S112S01 Series/S116S01 Series ■ Absolute Maximum Ratings (Ta = 25˚C ) Parameter Symbol Rating Unit Forward current IF 50 mA Input Reverse voltage VR 6 V RMS ON-state S112S01 Series *412 A rms I current T S116S01 Series *516 A rms *1 AC 60Hz sine wave, Tj = 25˚C *1 Peak one cycle S112S01 Series 120 A start I surge surge current S116S01 Series 160 A *2 AC 60Hz for 1 minute, 40 to 60 S112S01 / S112S02 % RH. Apply voltages between Repetitive peak S116S01 / S116S02 400 V Output V input and output by the OFF-state voltage DRM S212S01 / S212S02 S216S01 / S216S02 600 V dielectric withstand voltage S112S01 / S112S02 Non-repetitive peak tester with zero-cross circuit. S116S01 / S116S02 400 V V ( Input and output shall be short- OFF-state voltage DSM S212S01 / S212S02 S216S01 / S216S02 600 V ed respectively ) . Critical rate of rise of ON-state current dI/dt 50 A/µ s ( Note ) Operating frequency f 45 to 65 Hz When the isolation voltage is necessary at using external *2 Isolation voltage Viso 4 000 V rms heat sink, please use the in- Operating temperature Topr - 25 to + 100 ˚C sulation sheet. Storage temperature T *3 For 10 seconds stg - 30 to + 125 ˚C *4 T *3 C<= 70˚C Soldering temperature Tsol 260 ˚C *5 TC<=60˚C ■ Electrical Characteristics (Ta = 25˚C ) Parameter Symbol Conditions MIN. TYP. MAX. Unit Forward voltage V F IF = 20mA - 1.2 1.4 V Input Reverse current IR V R = 3V - - 10- 4 A Repetitive peak OFF-state current I DRM V D = V DRM - - 10- 4 A S112S01 Series Resistance load - - 1.5 V rms ON-state voltage V IF = 20mA, IT = 12Arms T S116S01 Series Resistance load I - - 1.5 V rms F = 20mA, IT = 16Arms Holding current IH - - - 50 mA Output Critical rate of rise of OFF-state voltage dV/dt V D = 2/3 • V DRM 30 - - V/µ s Critical rate of rise of commutating ( dV/dt )C T j = 125˚C, VD = 400V , *6 5 - - V/µ s OFF-state voltage Zero-cross voltage S112S02 / S212S02 S116S02 / S216S02 V OX IF = 8mA - - 35 V Minimum trigger S112S01 / S212S01 V D = 12V, R L= 30 S116S01 / S216S01 Ω - - 8 mA I FT current S112S02 / S212S02 S116S02 / S216S02 V D = 6V, R L= 30 Ω - - 8 mA Transfer Isolation resistance R ISO DC500V, RH = 40 to 60 % 1010 - - Ω charac- S112S01 / S212S01 S116S01 / S216S01 - - 1 ms teristics Turn-on time t on AC 50Hz S112S02 / S212S02 S116S02 / S216S02 - - 10 ms Turn-off time t off AC 50Hz - - 10 ms Thermal resistance S112S01 series - - 3.8 - ˚C/W ( Between junction and case) R th(j - c) S116S01 series - - 3.3 - ˚C/W Thermal resistance ( Between junction and ambience ) R th(j - a) - - 40 - ˚C/W *6 S112S01 Series : dI T /dt = - 6A/ms S116S01 Series : dI T /dt = - 8A/ms