link to page 5 link to page 8 link to page 8 link to page 8 STL200N45LF7Electrical characteristicsTable 7: Source-drain diodeSymbolParameterTest conditionsMin. Typ. Max. Unit V (1) SD Forward on voltage ISD = 36 A, VGS = 0 V - 1.1 V trr Reverse recovery time - 48 ns ID = 36 A, di/dt = 100 A/µs, Reverse recovery Qrr V - 55 nC DD = 36 V, (see Figure 15: "Test charge circuit for inductive load switching Reverse recovery and diode recovery times") IRRM - 2.3 A current Notes: (1)Pulsed: pulse duration = 300 µs, duty cycle 1.5% DocID027980 Rev 4 5/14