TABLE I. Electrical performance characteristics – Continued. 1/ Test Symbol Conditions 2/ Temperature, Device Limits Unit TA type Min Max Frequency range 9 GHz to 11 GHz Frequency range +25C 01 9 11 GHz Gain +25C 01 14 typical dB 12 Gain variation over -55C to +125C 01 0.012 typical dB/C temperature Noise figure NF +25C 01 1.8 typical dB Return loss Input +25C 01 14 typical dB Output +25C 01 10 typical dB Output Power for 1 dB OP1dB +25C 01 14 typical dBm compression 11 Saturated output power PSAT +25C 01 18 typical dBm Third order intercept OIP3 Measurement taken at output +25C 01 31 typical dBm power (POUT) per tone = 0 dBm Second order intercept OIP2 Measurement taken at output +25C 01 49.5 typical dBm power (POUT) per tone = 0 dBm Power added efficiency PAE Measure at PSAT +25C 01 15.5 typical % Supply Supply current IDQ +25C 01 60 typical mA Supply voltage VDD +25C 01 5 typical V 2 6 1/ Testing and other quality control techniques are used to the extent deemed necessary to assure product performance over the specified temperature range. Product may not necessarily be tested across the full temperature range and all parameters may not necessarily be tested. In the absence of specific parametric testing, product performance is assured by characterization and/or design. 2/ Unless otherwise specified, VDD = +5 V, supply current (IDQ) = 60 mA, RBIAS = 1.47 k, and TA = +25C. DLA LAND AND MARITIME SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIOA16236V62/21602 REV PAGE 7