TABLE IIA. Electrical test requirements. Test requirements Subgroups Subgroups (in accordance with (in accordance with MIL-STD-883, MIL-PRF-38535, table III) method 5005, table I) Device Device Device class M class Q class V Interim electrical --- --- 1 parameters (see 4.2) Final electrical 1,2,3 1/ 1,2,3 1/ 1,2,3 2/ parameters (see 4.2) Group A test 1,2,3 1,2,3 1,2,3 requirements (see 4.4) Group C end-point electrical 1 1 1,2,3 2/ parameters (see 4.4) Group D end-point electrical 1 1 1,2,3 parameters (see 4.4) Group E end-point electrical --- 1 1 parameters (see 4.4) 1/ PDA applies to subgroup 1. 2/ Delta limits as specified in TABLE IIB shall be computed with reference to the previous interim electrical parameters. Delta parameters are excluded from PDA. TABLE IIB. Burn-in and operating life test delta parameters. 1/ Parameter Delta limits Units IS 1 mA VOS 1 mV IIB 0.5 A 1/ Deltas are performed at room temperature. STANDARD SIZE 5962-96839MICROCIRCUIT DRAWINGA DLA LAND AND MARITIME REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 F 10 DSCC FORM 2234 APR 97