1.3 Absolute maximum ratings. 1/ Supply voltage (VS) .. 12.6 V Power dissipation (PD) ... 360 mW 2/ Common mode input voltage (VIN) .. VS Differential input voltage ... 4 V Storage temperature range (TSTG) .. -65C to +125C Lead temperature (soldering, 10 seconds) ... +300C Junction temperature range (TJ) .. 150C 1.4 Recommended operating conditions. 3/ Supply voltage range (VS) .. 5 V Operating free-air temperature range (TA) ... -55C to +105C 1.5 Thermal characteristics. Thermal resistance, junction to ambient (JA) .. 125C/W 1/ Stresses beyond those listed under “absolute maximum rating” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. 2/ Power dissipation arrived by PD = (TJ – TA) / JA. PD = (150 – 105) / 125 = 0.36 W 3/ Use of this product beyond the manufacturers design rules or stated parameters is done at the user’s risk. The manufacturer and/or distributor maintain no responsibility or liability for product used beyond the stated limits. DLA LAND AND MARITIME SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIOA16236V62/12644 REV A PAGE 3