Data SheetADIS16240ABSOLUTE MAXIMUM RATINGS Table 3. Stresses above those listed under Absolute Maximum Ratings ParameterRating may cause permanent damage to the device. This is a stress Acceleration rating only; functional operation of the device at these or any Any Axis, Unpowered 2000 g other conditions above those indicated in the operational Any Axis, Powered 2000 g section of this specification is not implied. Exposure to absolute VDD to GND −0.3 V to +3.6 V maximum rating conditions for extended periods may affect Digital Input Voltage to GND −0.3 V to VDD + 0.3 V device reliability. Analog Inputs to GND −0.3 V to VDD + 0.3 V Operating Temperature Range −40°C to +85°C Storage Temperature Range −65°C to +150°C ESD CAUTION Rev. C | Page 5 of 20 Document Outline Features Applications Functional Block Diagram General Description Revision History Specifications Timing Specifications Timing Diagrams Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Theory of Operation Sensing Element Data Sampling and Processing User Interface SPI Interface User Registers Capture Basic Operation SPI Write Commands Memory Map Output Data Registers Processing Sensor Data Event Recorder Internal Trigger Setup External Trigger Setup Buffer Memory Configuration Event Organization Reading Event Data Transient Behavior During Capture Operational Control Internal Sample Rate Global Commands Input/Output Lines Offset Adjustment Diagnostics Clock Checksum Flash Memory Endurance Management Applications Information Assembly Interface Printed Circuit Board (PCB) Outline Dimensions Ordering Guide