Specifications Equations Frequency Option 004/020/026: Isolation (dB) = 90 – (30/26.5)F, where F is specified in GHz Insertion loss (dB) = 0.35 + (0.45/26.5)F, where F is specified in GHz Frequency Options 040/050/067 Isolation (dB): 100 - (30/26.5)F, where F is specified in GHz (formula doesn’t apply when F > 26.5 GHz) Insertion loss (dB)Option 040: 0.35 + (0.45/26.5)F, where F is specified in GHz Option 050: 0.20 + (0.80/50)F, where F is specified in GHz Option 067: 0.35 + (0.45/26.5)F, where F is specified in GHz (DC to 26.5 GHz) 0.59 + (0.53/67)F, where F is specified in GHz (26.5 to 67 GHz) Option 301 and 302 Isolation (dB): 125 - (35/26.5)F, where F is specified in GHz (formula doesn’t apply when F > 26.5 GHz) Insertion loss (dB): 0.20 + (0.45/26.5)F, where F is specified in GHz 5 Document Outline High Performance Electromechanical Switches for Microwave and RF Manufacturing Test Systems Reduce Downtime Raise your Standards Increase Flexibility and Productivity Technology Operation and Driving Specifications Specifications Equations Supplemental Specifications and Characteristics Typical Performance Environmental Specifications Mechanical Dimensions Ordering Information Related Literatures More RF & Microwave Test Accessories