MOC8101, MOC8102, MOC8103, MOC8104 www.vishay.com Vishay Semiconductors CURRENT TRANSFER RATIO (Tamb = 25 °C, unless otherwise specified) PARAMETERTEST CONDITIONPARTSYMBOLMIN.TYP.MAX.UNIT MOC8101 CTR 50 - 80 % MOC8102 CTR 73 - 117 % Current transfer ratio VCE = 10 V, IF = 10 mA MOC8103 CTR 108 - 173 % MOC8104 CTR 160 - 256 % SWITCHING CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified) PARAMETERTEST CONDITIONSYMBOLMIN.TYP.MAX.UNIT Turn-on time VCC = 10 V, IC = 2.0 mA, RL = 100 Ω ton - 3.0 - μs Turn-off time VCC = 10 V, IC = 2.0 mA, RL = 100 Ω toff - 2.3 - μs Rise time VCC = 10 V, IC = 2.0 mA, RL = 100 Ω tr - 2.0 - μs Fall time VCC = 10 V, IC = 2.0 mA, RL = 100 Ω tf - 2.0 - μs Cut off frequency fco - 250 - kHz SAFETY AND INSULATION RATINGS PARAMETERTEST CONDITIONSYMBOLVALUEUNIT Climatic classification According to IEC 68 part 1 55 / 100 / 21 Comparative tracking index CTI 175 Maximum rated withstanding isolation voltage t = 1 min VISO 4420 VRMS Maximum transient isolation voltage VIOTM 10 000 V Maximum repetitive peak isolation voltage VIORM 890 V VIO = 500 V, Tamb = 25 °C RIO ≥ 1012 Ω Isolation resistance VIO = 500 V, Tamb = 100 °C RIO ≥ 1011 Ω Output safety power PSO 400 mW Input safety current ISI 275 mA Input safety temperature TSI 175 °C Creepage distance Standard DIP-6 ≥ 7 mm Clearance distance Standard DIP-6 ≥ 7 mm Creepage distance 400 mil DIP-6 ≥ 8 mm Clearance distance 400 mil DIP-6 ≥ 8 mm Insulation thickness DTI ≥ 0.4 mm Note • As per IEC 60747-5-5, § 7.4.3.8.2, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings. Compliance with the safety ratings shall be ensured by means of protective circuits Rev. 1.8, 13-Apr-2023 3 Document Number: 83660 For technical questions, contact: optocoupleranswers@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000