Datasheet 74HC595 (Diodes) - 4

FabricanteDiodes
Descripción8-bit Shift Register With 8-bit Output Register
Páginas / Página11 / 4 — 74HC595. Absolute Maximum Ratings. Symbol. Description. Rating. Unit. …
Formato / tamaño de archivoPDF / 608 Kb
Idioma del documentoInglés

74HC595. Absolute Maximum Ratings. Symbol. Description. Rating. Unit. Recommended Operating Conditions. Parameter. Conditions. Min. Max

74HC595 Absolute Maximum Ratings Symbol Description Rating Unit Recommended Operating Conditions Parameter Conditions Min Max

Línea de modelo para esta hoja de datos

Versión de texto del documento

74HC595 Absolute Maximum Ratings
(Note 4) (@TA = +25°C, unless otherwise specified.)
Symbol Description Rating Unit
ESD HBM Human Body Model ESD Protection 2 kV ESD CDM Charged Device Model ESD Protection 1 kV ESD MM Machine Model ESD Protection 200 V VCC Supply Voltage Range -0.5 to +7.0 V VI Input Voltage Range -0.5 to +7.0 V Vo Voltage Applied to Output in High or Low State -0.3 to VCC +0.5 V IIK Input Clamp Current VI < -0.5V -20 mA IIK Input Clamp Current VI > VCC +0.5V 20 mA IOK Output Clamp Current VO < -0.5V -20 mA IOK Output Clamp Current VO > VCC +0.5V 20 mA Q7 Standard Output ±25 mA IO Continuous Output Current Qn Bus Driver Outputs ±35 mA ICC Continuous Current through Vdd or GND 70 mA IGND Continuous Current through Vdd or GND -70 mA TJ Operating Junction Temperature -40 to +150 °C TSTG Storage Temperature -65 to +150 °C PTOT Total Power Dissipation 500 mW Note: 4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should be within recommend values.
Recommended Operating Conditions
(Note 5) (@TA = +25°C, unless otherwise specified.)
Symbol Parameter Conditions Min Max Unit
VCC Supply Voltage  2.0 6.0 V VI Input Voltage  0 VCC V VO Output Voltage Active Mode 0 VCC V VCC = 2.0V  1000 ns/V Δt/ΔV Input Transition Rise or Fall Rate VCC = 4.5V  500 VCC = 6.0V  400  TA Operating Free-Air Temperature  -40 +125 °C Note: 5. Unused inputs should be held at VCC or Ground. 74HC595 4 of 11 November 2018 Document number: DS35492 Rev. 4 - 2
www.diodes.com