link to page 4 link to page 4 ADG201A-EPABSOLUTE MAXIMUM RATINGS TA = 25°C, unless otherwise noted. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress Table 3. rating only; functional operation of the device at these or any ParameterRating other conditions above those indicated in the operational VDD to VSS 44 V section of this specification is not implied. Exposure to absolute VDD to GND 25 V maximum rating conditions for extended periods may affect VSS to GND −25 V device reliability. Analog Inputs1 VSS − 0.3 V to VDD + 0.3 V Digital Inputs1 VSS − 2 V to VDD + 2 V or 20 mA Only one absolute maximum rating may be applied at a time. (whichever occurs first) Pulsed Current, S or D 70 mA (pulsed at 1 ms, ESD CAUTION 10% duty cycle maximum) Continuous Current, S or D 30 mA Operating Temperature Range −55°C to +125°C Storage Temperature Range −65°C to +150°C Power Dissipation Up to +75°C 470 mW Derates above +75°C by 6 mW/°C Lead Soldering Reflow, Peak Temperature 260 (+0/−5)°C Time at Peak Temperature 20 sec to 40 sec 1 Overvoltages at IN, S, or D are clamped by internal diodes. Current should be limited to the maximum ratings given. Rev. 0 | Page 4 of 8 Document Outline Features Enhanced Product Features Functional Block Diagram General Description Product Highlights Revision History Specifications Dual Supply Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Test Circuits Outline Dimensions Ordering Guide