ADG604ABSOLUTE MAXIMUM RATINGS1 Junction Temperature . 150°C (TA = 25°C unless otherwise noted) TSSOP Package V DD to VSS . 13 V JA Thermal Impedance . 150°C/W V DD to GND . –0.3 V to +6.5 V JC Thermal Impedance . 27°C/W V Lead Temperature, Soldering (10 seconds) . 300°C SS to GND . +0.3 V to –6.5 V Analog Inputs2 . V IR Reflow, Peak Temperature . 220°C SS –0.3 V to VDD + 0.3 V Digital Inputs2 . –0.3 V to VDD + 0.3 V or . 30 mA, Whichever Occurs First NOTES 1Stresses above those listed under Absolute Maximum Ratings may cause perma- Peak Current, S or D . 20 mA nent damage to the device. This is a stress rating only; functional operation of the (Pulsed at 1 ms, 10% Duty Cycle Max) device at these or any other conditions above those listed in the operational Continuous Current, S or D . 10 mA sections of this specification is not implied. Exposure to absolute maximum rating Operating Temperature Range conditions for extended periods may affect device reliability. Only one absolute maximum rating may be applied at any one time. (Y Version) . –40°C to +125°C 2Overvoltages at EN, A0, A1, S, or D will be clamped by internal diodes. Current Storage Temperature Range . –65°C to +150°C should be limited to the maximum ratings given. PIN CONFIGURATIONTable I. Truth TableA1A0ENON SwitchA0114 A1 X X 0 None EN213 GNDADG604 0 0 1 1 VSS 312 VDD 0 1 1 2 TOP VIEWS1411 S3(Not To Scale) 1 0 1 3 S2510 S4 1 1 1 4 D 69NCNC78NCNC = NO CONNECTCAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although WARNING! the ADG604 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are ESD SENSITIVE DEVICE recommended to avoid performance degradation or loss of functionality. REV. A –5–