AOZ8S303BLS-24Electrical Characteristics TA = 25°C unless otherwise specified. ITLP2ITLP1 V V TLP2 1 TLP R DNY I I TLP2 TL 1 P IHoldVRWM VTLP2 VTLP1ITVBRVHold IRIR VHoldVBRITVTLP1 VTLP2 VRWMIHoldBidirectionalTVSITLP1ITLP2SymbolParameterConditionsMin.Typ.Max.Units VRWM Reverse Working Voltage 24 V VBR Reverse Breakdown Voltage IT = 100 µA 27 29 32 V IR Reverse Leakage Current Max. VRMW 1 50 nA Clamping Voltage(3)(4) ITLP = 1 A 2.5 (100ns Transmission Line Pulse) ITLP = 16 A 6 VCL V Clamping Voltage(3) IPP = 1 A 2.5 (IEC61000-4-5, 8/20 µs) IPP = 9 A 6.5 RDNY Dynamic Resistance(3)(4) ITLP = 1 A to 16 A 0.25 Ω CJ Junction Capacitance VI/O = 0 V, f = 1 MHz 0.20 0.25 pF Notes: 3. These specifications are guaranteed by design and characterization. 4. Measurements performed using a 100ns Transmission Line Pulse (TLP) system. Rev. 2.0 March 2021 www.aosmd.com Page 3 of 6