ADH519STABLE IIA – ELECTRICAL TEST REQUIREMENTS:Subgroups (in accordance withTest RequirementsMIL-PRF-38535, Table III) Interim Electrical Parameters 1, 4 Final Electrical Parameters 1, 4 1/ 2/ Group A Test Requirements 1, 2, 3, 4, 5, 6 Group C end-point electrical parameters 1, 4 2/ Group D end-point electrical parameters 1, 4 Group E end-point electrical parameters 1, 4 3/ Table IIA Notes: 1/ PDA applies to Table I subgroup 1 and Table IIB delta parameters. 2/ See Table IIB for delta parameters 3/ Parameters noted in Table I are not tested post irradiation. TABLE IIB – BURN-IN / LIFE TEST DELTA LIMITS 1/ 2/ 3/ParameterSymbolDeltaUnits Gain 18 GHz S21 ±1.0 dB Gain 28 GHz S21 ±1.5 dB Gain 31 GHz S21 ±1.5 dB Supply Current IDD ±10 % Table IIB Notes: 1/ 240 hour burn in and 1000 hour life test (group C) end point electrical parameters. 2/ Deltas are performed at room temperature TA = +25°C only. 3/ Deltas apply with VDD1 = VDD2 = VDD3 = 3.0V unless otherwise noted ASD0016589 Rev.A | Page 5 of 8