OP400Table II - Electrical Characteristics for Qual Samples Sub- Limit Limit Parameter Symbol Conditions 1/ Units groups Min Max 1 -150 +150 Input Offset Voltage V µ IO V 2, 3 -270 +270 1 -1 +1 Input Offset Current IIO VCM = 0V nA 2, 3 -2.5 +2.5 1 -3 +3 Input Bias Current ±IIB VCM = 0V nA 2, 3 -5 +5 Input Voltage Range IVR 1, 2, 3 ±12 V Common Mode Rejection 1 120 Ratio CMRR VCM = IVR dB 2, 3 115 Power Supply Rejection 1 1.8 PSRR V µV/V Ratio S = ±3V to ±18V 2, 3 3.2 1 2.9 Supply Current 2/ ISY No Load mA 2, 3 3.1 4 1500 Large Signal Voltage Gain AVS VOUT = ±10V, RL = 2kΩ V/mV 5, 6 1000 Output Voltage Swing +VOP RL = 2kΩ 4, 5, 6 ±11 V Average Input Offset Voltage Drift TCVIO -55°C ≤ TA ≤ +125°C 8 1.2 µV/°C Table II Notes: Table III - Life Test Endpoint and Delta Parameter(Product is tested in accordance with Table II with the following exceptions) Post Post Post Life Post Life Sub- Burn In Burn In Test Test Life Test Parameter Symbol Units groups Limit Limit Limit Limit Delta Min Max Min Max 1 ±225 ±300 ±75 Input Offset Voltage VIO µV 2, 3 ±420 1 ±5 ±7 ±2 Input Bias Current ±IIB nA 2, 3 ±9 1 ±2 ±2.5 Input Offset Current IIO nA 2, 3 ±4.5