Data SheetADCMP350/ADCMP354/ADCMP356SPECIFICATIONS VCC = full operating range, TA = −40°C to +125°C, unless otherwise noted. Table 2. ParameterMinTypMaxUnitTest Conditions/Comments SUPPLY Operating Voltage Range VCC 2.25 5.5 V VIN 0 22 V Supply Current 10 15 µA VIN THRESHOLD VCC = 3.3 V Rising 0.579 0.6 0.621 V TA = −40°C to +85°C 0.579 0.6 0.624 V TA = −40°C to +125°C Falling 0.564 0.585 0.606 V TA = −40°C to +85°C 0.564 0.585 0.609 V TA = −40°C to +125°C INPUT BIAS CURRENT 10 nA VIN = 0.6 V 170 µA VIN = 22 V THRESHOLD TEMPERATURE COEFFICIENT 30 ppm/°C VIN TO OUT DELAY 5 µs VIN = VTH to (VTH − 100 mV) OUT VOLTAGE Low 0.4 V VIN < VTH minimum, ISINK = 1.2 mA High 0.8 × VCC V VIN > VTH maximum, ISOURCE = 500 µA, push-pull only OUTPUT TIME COUT = 15 pF Rise 30 ns Fall 45 ns OUTPUT LEAKAGE CURRENT 1 µA OUT = 22 V, open-drain only Rev. E | Page 3 of 10 Document Outline FEATURES APPLICATIONS FUNCTIONAL BLOCK DIAGRAMS GENERAL DESCRIPTION TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS APPLICATIONS INFORMATION ADDING HYSTERESIS VOLTAGE DETECTOR OUTLINE DIMENSIONS ORDERING GUIDE