AOZ6763DIAbsolute Maximum Ratings (1) Maximum Operating Ratings (3) Exceeding the Absolute Maximum Ratings may damage the The device is not guaranteed to operate beyond the device. Maximum Operating ratings. ParameterRatingParameterRating Supply Voltage (VIN), EN (VEN) 20V Supply Voltage (VIN) 4.5V to 18V LX to GND -0.3V to VIN+0.3V Output Voltage Range 0.6V to 0.65*VIN LX to GND (20ns) -5V to 22V Ambient Temperature (TA) -40°C to +85°C VCC, FB to GND -0.3V to 6V Package Thermal Resistance 50°C/W VBST TO LX 6V DFN 3x3 (θJA)(4) Notes: Junction Temperature (TJ) +150°C 3. The device is not guaranteed to operate beyond the Maximum Storage Temperature (TS) -65°C to +150°C Operating ratings. ESD Rating(2) 2kV 4. The value of θJA is measured with the device mounted on a 1-in2 Notes: FR-4 four layer board with 2oz copper and Vias, in a still air environ- ment with T 1. Exceeding the Absolute Maximum ratings may damage the device. A = 25°C. The value in any given application depends on the user’s specification board design. 2. Devices are inherently ESD sensitive, handling precautions are required. Human body model rating: 1.5k in series with 100pF. Electrical Characteristics TA = 25°C, VIN = VEN = 12V, VOUT = 3.3V, unless otherwise specified. Specifications in bold indicate an ambient temperature range of -40°C to +85°C. These specifications are guaranteed by design. SymbolParameterConditionsMin.Typ.MaxUnits VIN Supply Voltage 4.518 V V 4.1 4.49 V V IN rising UVLO Input Under-Voltage Lockout Threshold VIN falling 3.2 3.7 V IIN Supply Current (Quiescent) IOUT = 0V, VFB = 1.2V, VEN > 2V 260 A IOFF Shutdown Supply Current VEN = 0V 0.1 1 A VFB Feedback Voltage TA = 25°C 0.591 0.6 0.609 V RO Load Regulation PWM mode 500mA < ILoad < 3A 0.5 % SV Line Regulation 4.5V < VIN < 18V 1 % IFB Feedback Voltage Input Current 200 nA Off threshold 0.6 V VEN EN Input Threshold On threshold 2 V VHYS EN Input Hysteresis 300 mV IEN EN Input Current VEN = 5V 2.5 4 A tSS SS Time 2.6 ms Modulator fO Frequency 1100 1250 1400 kHz DMAX Maximum Duty Cycle 65 70 % TMIN Controllable Minimum Duty Cycle 30 ns Protection ILIM Current Limit 3.5 4.5 A TOTP T 150 °C Over Temperature Shutdown Limit J rising TJ falling 100 °C Output Stage RHS High-Side Switch On-Resistance BST - LX = 5V 145 m RLS Low-Side Switch On-Resistance 80 m Rev. 1.0 October 2019 www.aosmd.com Page 3 of 15