link to page 13 ADuM6020/ADuM6028Data SheetREGULATORY APPROVALSTable 7. UL1CSAVDE2 CQC(Pending) Recognized Under 1577 Approved under CSA Component DIN V VDE V 0884-10 Certified under Component Recognition Acceptance Notice 5A (VDE V 0884-10):2006-12 CQC11-471543-2012 Program1 Single Protection, 5000 V rms CSA 60950-1-07+A1+A2 and Reinforced insulation GB4943.1-2011: Isolation Voltage IEC 60950-1, second edition, +A1+A2 565 V peak, surge isolation Basic insulation at voltage (VIOSM) = 6250 V peak 780 V rms (1103 V peak) Basic insulation at 830 V rms (1173 V peak) Transient voltage (VIOTM) = Reinforced insulation at 8000 V peak 390 V rms (552 V peak) Reinforced insulation at 415 V rms (586 V peak) IEC 60601-1 Edition 3.1: Reinforced insulation (2 MOPP), 250 V rms (353 V peak) CSA 61010-1-12 and IEC 61010-1 third edition Basic insulation at 600 V rms mains, 830 V secondary (1173 V peak) Reinforced insulation at 300 V rms mains, 415 V secondary (586 V peak) File E214100 File 205078 File 2471900-4880-0001 File (pending) 1 In accordance with UL 1577, each ADuM6020 and ADuM6028 are proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec. 2 In accordance with DIN V VDE V 0884-10, each ADuM6020 and ADuM6028 are proof tested by applying an insulation test voltage ≥ 1059 V peak for 1 sec (partial discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval. INSULATION AND SAFETY RELATED SPECIFICATIONS For additional information, see www.analog.com/icouplersafety. Table 8. ADuM6020 Insulation and Safety Parameter SymbolValueUnitTestConditions/Comments Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration Minimum External Air Gap (Clearance) L (I01) 8.3 mm min Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (Creepage) L (I02) 8.3 mm min Measured from input terminals to output terminals, shortest distance path along body Minimum Clearance in the Plane of the Printed L (PCB) 8.3 mm min Measured from input terminals to output terminals, Circuit Board (PCB Clearance) shortest distance through air, line of sight, in the PCB mounting plane Minimum Internal Gap (Internal Clearance) 25.5 μm min Insulation distance through insulation Tracking Resistance (Comparative Tracking Index) CTI >600 V DIN IEC 112/VDE 0303 Part 1 Material Group I Material Group (DIN VDE 0110, 1/89, Table 1) Table 9. ADuM6028 Insulation and Safety Parameter SymbolValueUnitTestConditions/Comments Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration Minimum External Air Gap (Clearance) L (I01) 8.3 mm min Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (Creepage) L (I02) 8.3 mm min Measured from input terminals to output terminals, shortest distance path along body Minimum Clearance in the Plane of the Printed L (PCB) 8.3 mm min Measured from input terminals to output terminals, Circuit Board (PCB Clearance) shortest distance through air, line of sight, in the PCB mounting plane Minimum Internal Gap (Internal Clearance) 25.5 μm min Insulation distance through insulation Tracking Resistance (Comparative Tracking Index) CTI >600 V DIN IEC 112/VDE 0303 Part 1 Material Group I Material Group (DIN VDE 0110, 1/89, Table 1) Rev. B | Page 6 of 20 Document Outline Features Applications Functional Block Diagrams General Description Revision History Specifications Electrical Characteristics—5 V Primary Input Supply/5 V Secondary Isolated Supply Electrical Characteristics—5 V Primary Input Supply/3.3 V Secondary Isolated Supply Electrical Characteristics—3.3 V Primary Input Supply/3.3 V Secondary Isolated Supply Regulatory Approvals Insulation and Safety Related Specifications Package Characteristics DIN V VDE V 0884-10 (VDE V 0884-10) Insulation Characteristics Recommended Operating Conditions Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Truth Table Typical Performance Characteristics Theory of Operation Applications Information PCB Layout Thermal Analysis EMI Considerations Insulation Lifetime Surface Tracking Insulation Wear Out Calculation and Use of Parameters Example Outline Dimensions Ordering Guide