Datasheet VSC7512 (Microchip) - 9

FabricanteMicrochip
Descripción10 Port Unmanaged Industrial Ethernet Switch
Páginas / Página325 / 9 — Figures
Formato / tamaño de archivoPDF / 4.8 Mb
Idioma del documentoInglés

Figures

Figures

Línea de modelo para esta hoja de datos

Versión de texto del documento

link to page 22 link to page 22 link to page 23 link to page 25 link to page 27 link to page 28 link to page 29 link to page 42 link to page 47 link to page 51 link to page 52 link to page 54 link to page 55 link to page 56 link to page 57 link to page 59 link to page 59 link to page 59 link to page 65 link to page 68 link to page 70 link to page 71 link to page 73 link to page 76 link to page 82 link to page 95 link to page 96 link to page 106 link to page 111 link to page 113 link to page 114 link to page 114 link to page 116 link to page 118 link to page 126 link to page 135 link to page 137 link to page 139 link to page 141 link to page 144 link to page 145 link to page 146 link to page 150 link to page 152 link to page 157 link to page 163 link to page 165 link to page 166 link to page 166 link to page 167 link to page 167 link to page 167 link to page 167 link to page 168 link to page 171
Figures
Figure 1 Block Diagram . 7 Figure 2 Basic and Advanced Frame Classification . 8 Figure 3 Versatile Content Aware Processor . 10 Figure 4 Default Egress Scheduler and Shaper Configuration . 12 Figure 5 Alternative Egress Scheduler and Shaper Configuration . 13 Figure 6 Advanced Frame Rewriting . 14 Figure 7 SERDES1G Loopback Modes . 27 Figure 8 SERDES6G Loopback Modes . 32 Figure 9 Register Space Layout . 36 Figure 10 Cat5 Media Interface . 37 Figure 11 Low Power Idle Operation . 39 Figure 12 Wake-On-LAN Functionality . 40 Figure 13 Inline Powered Ethernet Switch . 41 Figure 14 ActiPHY State Diagram . 42 Figure 15 Far-End Loopback . 44 Figure 16 Near-End Loopback . 44 Figure 17 Connector Loopback . 44 Figure 18 Counter Layout (SYS:STAT:CNT) Per View . 50 Figure 19 VLAN Acceptance Filter . 53 Figure 20 QoS and DP Basic Classification Flow . 55 Figure 21 Basic DSCP Classification Flow Chart . 56 Figure 22 Basic VLAN Classification Flow . 58 Figure 23 VCAP Functional Overview . 61 Figure 24 IS1 Entry Type Overview . 67 Figure 25 IS2 Half Entry Type Overview . 80 Figure 26 IS2 Half Entry Type Overview . 81 Figure 27 SMAC_SIP Entry Type Overview . 91 Figure 28 VCAP Configuration Overview . 96 Figure 29 Entry Layout in Register Example . 98 Figure 30 Entry Layout in Register using Subwords Example . 99 Figure 31 Action Layout in Register Example . 99 Figure 32 Move Down Operation Example . 101 Figure 33 MAC Table Organization . 103 Figure 34 Analysis Steps . 111 Figure 35 Policer Pool Layout . 120 Figure 36 Queue System Overview . 122 Figure 37 Frame Reference . 124 Figure 38 Watermark Layout . 126 Figure 39 Low Power Idle Operation . 129 Figure 40 Egress Scheduler Port 0 . 130 Figure 41 Scheduler Element . 131 Figure 42 Tagging Overview . 135 Figure 43 Tag Construction (port tag, ES0 tag A, ES0 tag B) . 137 Figure 44 CPU Injection and Extraction . 142 Figure 45 CPU Injection and Extraction Prefixes . 148 Figure 46 VRAP Request Frame Format . 150 Figure 47 VRAP Response Frame Format . 151 Figure 48 VRAP Header Format . 151 Figure 49 READ Command . 152 Figure 50 WRITE Command . 152 Figure 51 READ-MODIFY-WRITE Command . 152 Figure 52 IDLE Command . 152 Figure 53 PAUSE Command . 153 Figure 54 Timing Distribution . 156 VMDS-10489 VSC7512 Datasheet Revision 4.2 ix Document Outline 1 Revision History 1.1 Revision 4.2 1.2 Revision 4.1 1.3 Revision 4.0 1.4 Revision 2.1 1.5 Revision 2.0 2 Product Overview 2.1 General Features 2.1.1 Layer 2 Switching 2.1.2 Layer 2 Multicast 2.1.3 Quality of Service 2.1.4 Security 2.1.5 Management 2.1.6 Product Parameters 2.2 Applications 2.3 Functional Overview 2.3.1 Frame Arrival 2.3.2 Basic and Advanced Frame Classification 2.3.3 Versatile Content Aware Processor (VCAP) 2.3.4 Policing 2.3.5 Layer-2 Forwarding 2.3.6 Shared Queue System and Egress Scheduler 2.3.7 Rewriter and Frame Departure 2.3.8 CPU Port Module 2.3.9 Synchronous Ethernet and Precision Time Protocol 2.3.10 CPU System and Interfaces 3 Functional Descriptions 3.1 Port Numbering and Mappings 3.1.1 Supported SerDes Interfaces 3.1.2 QSGMII 3.1.3 Miscellaneous Port Muxing 3.1.4 PCIe Mode 3.1.5 Logical Port Numbers 3.2 Port Modules 3.2.1 MAC 3.2.2 PCS 3.3 SERDES1G 3.3.1 SERDES1G Basic Configuration 3.3.2 SERDES1G Loopback Modes 3.3.3 Synchronous Ethernet 3.3.4 SERDES1G Deserializer Configuration 3.3.5 SERDES1G Serializer Configuration 3.3.6 SERDES1G Input Buffer Configuration 3.3.7 SERDES1G Output Buffer Configuration 3.3.8 SERDES1G Clock and Data Recovery (CDR) in 100BASE-FX 3.3.9 Energy Efficient Ethernet 3.3.10 SERDES1G Data Inversion 3.4 SERDES6G 3.4.1 SERDES6G Basic Configuration 3.4.2 SERDES6G Loopback Modes 3.4.3 Synchronous Ethernet 3.4.4 SERDES6G Deserializer Configuration 3.4.5 SERDES6G Serializer Configuration 3.4.6 SERDES6G Input Buffer Configuration 3.4.7 SERDES6G Output Buffer Configuration 3.4.8 SERDES6G Clock and Data Recovery (CDR) in 100BASE-FX 3.4.9 Energy Efficient Ethernet 3.4.10 SERDES6G Data Inversion 3.4.11 SERDES6G Signal Detection Enhancements 3.4.12 High-Speed I/O Configuration Bus 3.5 Copper Transceivers 3.5.1 Register Access 3.5.2 Cat5 Twisted Pair Media Interface 3.5.3 Wake-On-LAN and SecureOn 3.5.4 Ethernet Inline Powered Devices 3.5.5 IEEE 802.3af PoE Support 3.5.6 ActiPHY™ Power Management 3.5.7 Testing Features 3.5.8 VeriPHY™ Cable Diagnostics 3.6 Statistics 3.6.1 Port Statistics 3.6.2 Accessing and Clearing Counters 3.7 Basic Classifier 3.7.1 General Data Extraction Setup 3.7.2 Frame Acceptance Filtering 3.7.3 QoS, DP, and DSCP Classification 3.7.4 VLAN Classification 3.7.5 Link Aggregation Code Generation 3.7.6 CPU Forwarding Determination 3.8 VCAP 3.8.1 Port Configuration 3.8.2 VCAP IS1 3.8.3 VCAP IS2 3.8.4 VCAP ES0 3.8.5 Range Checkers 3.8.6 VCAP Configuration 3.8.7 Advanced VCAP Operations 3.9 Analyzer 3.9.1 MAC Table 3.9.2 VLAN Table 3.9.3 Forwarding Engine 3.9.4 Analyzer Monitoring 3.10 Policers 3.10.1 Policer Allocation 3.10.2 Policer Burst and Rate Configuration 3.11 Shared Queue System 3.11.1 Buffer Management 3.11.2 Frame Reference Management 3.11.3 Resource Depletion Condition 3.11.4 Configuration Example 3.11.5 Watermark Programming and Consumption Monitoring 3.11.6 Advanced Resource Management 3.11.7 Ingress Pause Request Generation 3.11.8 Tail Dropping 3.11.9 Test Utilities 3.11.10 Energy Efficient Ethernet 3.12 Scheduler and Shapers 3.12.1 Scheduler Element 3.12.2 Egress Shapers 3.12.3 Deficit Weighted Round Robin 3.12.4 Round Robin 3.12.5 Shaping and DWRR Scheduling Examples 3.13 Rewriter 3.13.1 VLAN Editing 3.13.2 DSCP Remarking 3.13.3 FCS Updating 3.13.4 PTP Time Stamping 3.13.5 Special Rewriter Operations 3.14 CPU Port Module 3.14.1 Frame Extraction 3.14.2 Frame Injection 3.14.3 Node Processor Interface (NPI) 3.14.4 Frame Generation Engine for Periodic Transmissions 3.15 VRAP Engine 3.15.1 VRAP Request Frame Format 3.15.2 VRAP Response Frame Format 3.15.3 VRAP Header Format 3.15.4 VRAP READ Command 3.15.5 VRAP WRITE Command 3.15.6 VRAP READ-MODIFY-WRITE Command 3.15.7 VRAP IDLE Command 3.15.8 VRAP PAUSE Command 3.16 Layer 1 Timing 3.17 Hardware Time Stamping 3.17.1 Time Stamp Classification 3.17.2 Time of Day Generation 3.17.3 Hardware Time Stamping Module 3.17.4 Configuring I/O Delays 3.18 Clocking and Reset 3.18.1 Pin Strapping 4 VCore-Ie System and CPU Interfaces 4.1 VCore-Ie Configurations 4.2 Clocking and Reset 4.2.1 Watchdog Timer 4.3 Shared Bus 4.3.1 VCore-Ie Shared Bus Arbitration 4.3.2 Chip Register Region 4.3.3 SI Flash Region 4.3.4 PCIe Region 4.3.5 Starting the VCore-Ie CPU 4.3.6 Accessing the VCore-Ie Shared Bus 4.3.7 Paged Access to VCore-Ie Shared Bus 4.3.8 Software Debug and Development 4.4 VCore-Ie CPU 4.5 Load on-chip memory with code-image. For more information, see External CPU Support 4.5.1 Register Access and Multimaster Systems 4.5.2 Serial Interface in Slave Mode 4.5.3 MIIM Interface in Slave Mode 4.5.4 Access to the VCore Shared Bus 4.5.5 Mailbox and Semaphores 4.6 PCIe Endpoint Controller 4.6.1 Accessing Endpoint Registers 4.6.2 Enabling the Endpoint 4.6.3 Base Address Registers Inbound Requests 4.6.4 Outbound Interrupts 4.6.5 Outbound Access 4.6.6 Power Management 4.6.7 Device Reset Using PCIe 4.7 Frame DMA 4.7.1 DMA Control Block Structures 4.7.2 Enabling and Disabling FDMA Channels 4.7.3 Channel Counters 4.7.4 FDMA Events and Interrupts 4.7.5 FDMA Extraction 4.7.6 FDMA Injection 4.7.7 Manual Mode 4.8 VCore-Ie System Peripherals 4.8.1 SI Boot Controller 4.8.2 SI Master Controller 4.8.3 Timers 4.8.4 UARTs 4.8.5 Two-Wire Serial Interface 4.8.6 MII Management Controller 4.8.7 GPIO Controller 4.8.8 Serial GPIO Controller 4.8.9 Fan Controller 4.8.10 Temperature Sensor 4.8.11 Memory Integrity Monitor 4.8.12 Interrupt Controller 5 Features 5.1 Switch Control 5.1.1 Switch Initialization 5.2 Port Module Control 5.2.1 Port Reset Procedure 5.2.2 Port Counters 5.3 Layer-2 Switch 5.3.1 Basic Switching 5.3.2 Standard VLAN Operation 5.3.3 Provider Bridges and Q-in-Q Operation 5.3.4 Private VLANs 5.3.5 Asymmetric VLANs 5.3.6 Spanning Tree Protocols 5.3.7 IEEE 802.1X: Network Access Control 5.3.8 Link Aggregation 5.3.9 Simple Network Management Protocol (SNMP) 5.3.10 Mirroring 5.4 IGMP and MLD Snooping 5.4.1 IGMP and MLD Snooping Configuration 5.4.2 IP Multicast Forwarding Configuration 5.5 Quality of Service (QoS) 5.5.1 Basic QoS Configuration 5.5.2 IPv4 and IPv6 DSCP Remarking 5.5.3 Voice over IP (VoIP) 5.6 VCAP Applications 5.6.1 Notation for Control Lists Entries 5.6.2 Ingress Control Lists 5.6.3 Access Control Lists 5.6.4 Source IP Filter (SIP Filter) 5.6.5 DHCP Application 5.6.6 ARP Filtering 5.6.7 Ping Policing 5.6.8 TCP SYN Policing 5.7 CPU Extraction and Injection 5.7.1 Forwarding to CPU 5.7.2 Frame Extraction 5.7.3 Frame Injection 5.7.4 Frame Extraction and Injection Using An External CPU 6 Registers 7 Electrical Specifications 7.1 DC Specifications 7.1.1 Internal Pull-Up or Pull-Down Resistors 7.1.2 Reference Clock Inputs 7.1.3 PLL Clock Outputs 7.1.4 SERDES1G 7.1.5 SERDES6G 7.1.6 GPIO, SI, JTAG, and Miscellaneous Signals 7.1.7 Thermal Diode 7.2 AC Specifications 7.2.1 REFCLK Reference Clock (1G and 6G Serdes) 7.2.2 PLL Clock Outputs 7.2.3 SERDES1G 7.2.4 SERDES6G 7.2.5 Reset Timing Specifications 7.2.6 MIIM Timing Specifications 7.2.7 SI Boot Timing Master Mode Specifications 7.2.8 SI Timing Master Mode Specifications 7.2.9 SI Timing Slave Mode Specifications 7.2.10 JTAG Interface Specifications 7.2.11 Serial I/O Timing Specifications 7.2.12 Recovered Clock Outputs Specifications 7.2.13 Two-Wire Serial Interface Specifications 7.2.14 IEEE1588 Time Tick Output Specifications 7.3 Current and Power Consumption 7.4 Operating Conditions 7.4.1 Power Supply Sequencing 7.5 Stress Ratings 8 Pin Descriptions 8.1 Pin Diagram 8.2 Pins by Function 9 Package Information 9.1 Package Drawing 9.2 Thermal Specifications 9.3 Moisture Sensitivity 10 Design Guidelines 10.1 Power Supplies 10.2 Power Supply Decoupling 10.2.1 Reference Clock 10.2.2 Single-Ended REFCLK Input 10.3 Interfaces 10.3.1 General Recommendations 10.3.2 SerDes Interfaces (SGMII, 2.5GQSGMII) 10.3.3 Serial Interface 10.3.4 PCI Express Interface 10.3.5 Two-Wire Serial Interface 10.3.6 DDR3 SDRAM Interface 10.3.7 Thermal Diode External Connection 11 Ordering Information