may cause permanent damage to the device. These are stress ratings only. Functional operation of the device at these or any other conditions beyond those indicated under Operating Conditions is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Figure 5: Absolute Maximum Ratings over Operating Free-Air Temperature Range (unless otherwise noted) Symbol Parameter Min Max Unit
VDD Supply voltage (1) 6 V IO Output current ±10 mA Duration of short-circuit current at (or below) 25°C 5 s TA Operating free-air temperature range -25 85 °C TSTRG Storage temperature range -25 85 °C Lead temperature 1.6mm (1/16 inch) from case for 10 seconds 260 °C (S Package)
Note(s):
1. All voltages are with respect to GND.
Page 4 ams Datasheet
Document Feedback [v1-01] 2018-May-04 Document Outline General Description Key Benefits & Features Functional Block Diagram Pin Assignment Absolute Maximum Ratings Electrical Characteristics Operating Conditions Parameter Measurement Information Typical Operating Characteristics Package Mechanical Data Plastic Single-In-Line Side-Looker Package Ordering & Contact Information RoHS Compliant & ams Green Statement Copyrights & Disclaimer Document Status Revision Information Content Guide