Datasheet PPC (Cornell Dubilier) - 2

FabricanteCornell Dubilier
DescripciónType PPC, -55 ºC to + 125 ºC, Ultra-Thin Polymer Aluminum Electrolytic Capacitor
Páginas / Página8 / 2 — Type PPC, -55 ºC to + 125 ºC, Ultra-Thin Polymer Aluminum Electrolytic …
Formato / tamaño de archivoPDF / 450 Kb
Idioma del documentoInglés

Type PPC, -55 ºC to + 125 ºC, Ultra-Thin Polymer Aluminum Electrolytic Capacitor. Vibration Test. Level. Amplitude

Type PPC, -55 ºC to + 125 ºC, Ultra-Thin Polymer Aluminum Electrolytic Capacitor Vibration Test Level Amplitude

Línea de modelo para esta hoja de datos

Versión de texto del documento

Type PPC, -55 ºC to + 125 ºC, Ultra-Thin Polymer Aluminum Electrolytic Capacitor Vibration Test Level
The specimens, while deenergized or operating under the load conditions specified, shall be subjected to the vibration amplitude, frequency range, and duration specified for each case size. Level = 10g
Amplitude
The specimens shall be subjected to a simple harmonic motion having an amplitude of either 0.06-inch double amplitude (maximum total excursion) or peak level specified above, whichever is less. The tolerance on vibration amplitude shall be ±10 percent.
Frequency Range
The vibration frequency shall be varied logarithmically between the approxi- mate limits of 10 to 2,000 Hz.
Sweep Time and Duration
The entire frequency range of 10 to 2,000 Hz and return to 10 Hz shall be traversed in 20 minutes. This cycle shall be performed 12 times in each of three mutually perpendicular directions (total of 36 times), so that the motion shall be applied for a total period of approximately 12 hours. Interruptions are permitted provided the requirements for rate of change and test duration are met.
Mounting
Recommended mounting with 3M double sided VHB tape appropriate for mounting surfaces and to ensure the entire capacitor surface is held rigid.
Altitude
10,000 Feet
Endurance Life Test
Apply the maximum rated voltage for 2,000 hrs at +85 °C with full rated ripple current. After the test, return the capacitor to room temperature for 24 hours and then test. ∆C at 120Hz/+25 °C: ±20% of the initial ESR at 120Hz/+25 °C: ESR ≤ 200% of the initial DCL after 2 minute charge/+25 °C: ≤ 0.005CV
Shelf Life Test
Subject the capacitor to 1000 hrs at +125 °C without voltage. After the test, return the capacitor to room temperature for 24 hours and then test. ∆C at 120Hz/+25 °C: ±20% of the initial ESR at 120Hz/+25 °C: ESR ≤ 200% of the initial DCL after 2 minute charge/+25 °C: ≤ 0.005CV
Moisture Resistance Test
MIL-STD-202, method 106. After the test, return the capacitor to room temperature for 24 hours and then test. ∆C at 120Hz/+25 °C: ±20% of the initial ESR at 120Hz/+25 °C: ESR ≤ 200% of the initial
PPCE1001 -55 ºC to +125 ºC
DCL after 2 minute charge/+25 °C: ≤ 0.005CV
Polymer-Aluminum Electrolytic Capacitor Charge/Discharge Test Recommended mounting
Charge to rated Vdc and discharge to 0 Vdc, 100,000 cycles at 0.1 Hz, through a 0.22Ω resistor @ 25C. After the test, return the capacitor to room temperature
Solder Type
or 24 hours and then test. ∆C at 120Hz/+25 °C: ±20% of the initial ESR at 120Hz/+25 °C: ESR ≤ 200% of the initial DCL after 2 minute charge/+25 °C: ≤ 0.005CV
RoHS Compliant Stud Type CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 Hardware: M6≈1/4-20 stud / bolt Copper flat washer, M6 washer with 12 mm (0.472") OD Precaution: Ensure proper terminal spacing and stud / bolt size. CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830