Datasheet AK7864A (Asahi Kasei Microdevices) - 3

FabricanteAsahi Kasei Microdevices
Descripción3 channel LED Driver with Charge Pump
Páginas / Página13 / 3 — Functional Description. Power Down. Circuit reset
Formato / tamaño de archivoPDF / 302 Kb
Idioma del documentoInglés

Functional Description. Power Down. Circuit reset

Functional Description Power Down Circuit reset

Línea de modelo para esta hoja de datos

Versión de texto del documento

[AK7864A]
Functional Description

Power Down
Set PDN to Low at VDD power on, AK7864A will be in power down state. In power down state, the current inside AK7864A will be stopped, LED_R/G/B will be High-Z and CPOUT will be Low. 
Circuit reset
PDN is also carrying out the reset of an internal counter, please start supplying VDD to AK7864A by PDN=Low. The period of soft start of charge pump is decided at the internal counter. When soft start does not operate correctly, at the time of starting, incoming current will be large and the device may break. MS1336 - E - 00 3 2012/01