link to page 6 ADuM3221-EPEnhanced ProductDIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS These isolators are suitable for reinforced isolation only within the safety limit data. Maintenance of the safety data is ensured by protective circuits. The asterisk (*) marking on the package denotes DIN V VDE V 0884-10 approval for a 560 V peak working voltage. Table 6. DescriptionTest Conditions/CommentsSymbol Characteristic Unit Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms I to IV For Rated Mains Voltage ≤ 300 V rms I to III For Rated Mains Voltage ≤ 400 V rms I to II Climatic Classification 40/105/21 Pollution Degree per DIN VDE 0110, Table 1 2 Maximum Working Insulation Voltage V 560 V peak IORM Input to Output Test Voltage, Method B1 V × 1.875 = V , 100% production test, t = 1 sec, V 1050 V peak IORM PR m PR partial discharge < 5 pC Input to Output Test Voltage, Method A After Environmental Tests Subgroup 1 V × 1.6 = V , t = 60 sec, partial discharge < 5 pC V 896 V peak IORM PR m PR After Input and/or Safety Tests Subgroup 2 V × 1.2 = V , t = 60 sec, partial discharge < 5 pC V 672 V peak IORM PR m PR and Subgroup 3 Highest Allowable Overvoltage Transient overvoltage, t = 10 sec V 4000 V peak TR TR Safety Limiting Values Maximum value allowed in the event of a failure (see Figure 2) Case Temperature T 150 °C S Side 1 Current I 160 mA S1 Side 2 Current I 47 mA S2 Insulation Resistance at T V = 500 V R >109 Ω S IO S 200RECOMMENDED OPERATING CONDITIONS180Table 7.160mA)ParameterSymbol MinMaxUnit(140NTSIDE 1 Operating Junction T −55 +125 °C J 120 Temperature CURRE100 Supply Voltages1 V 3.0 5.5 V DD1 ING IT80 V 7.6 18 V DD2 IM V Rise Time t 1 V/µs L DD1 VDD1 Y60TSIDE 2E Common-Mode Transient −25 +25 kV/µs 40AF Immunity, Input to Output S20 Input Signal Rise and Fall 1 ms Times 0050100150200 002 CASE TEMPERATURE (°C) 1 14765- All voltages are relative to their respective ground. Figure 2. Thermal Derating Curve; Dependence of Safety Limiting Values on Case Temperature, per DIN V VDE V 0884-10 (Safety Limiting Current Is Defined as the Average Current at Maximum VDD) Rev. 0 | Page 6 of 12 Document Outline FEATURES ENHANCED PRODUCT FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ELECTRICAL CHARACTERISTICS—5 V OPERATION ELECTRICAL CHARACTERISTICS—3.3 V OPERATION PACKAGE CHARACTERISTICS REGULATORY INFORMATION INSULATION AND SAFETY RELATED SPECIFICATIONS DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS RECOMMENDED OPERATING CONDITIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS OUTLINE DIMENSIONS ORDERING GUIDE