X9312D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.) LimitsSymbolParameterMin.Typ.(4)Max.UnitTest Conditions ICC VCC active current (Increment) 1 3 mA CS = VIL, U/D = VIL or VIH and INC = 0.4V/2.4V @ max. tCYC ISB Standby supply current 500 1000 µA CS = VCC - 0.3V, U/D and INC = VSS or VCC - 0.3V ILI CS, INC, U/D input leakage current ±10 µA VIN = VSS to VCC VIH CS, INC, U/D input HIGH voltage 2 VCC + 1 V VIL CS, INC, U/D input LOW voltage -1 0.8 V C (5) IN CS, INC, U/D input capacitance 10 pF VCC = 5V, VIN = VSS, TA = 25°C, f = 1MHz ENDURANCE AND DATA RETENTIONParameterMin.Unit Minimum endurance 100,000 Data changes per bit Data retention 100 Years Notes: (4) Typical values are for TA = 25°C and nominal supply voltage. (5) This parameter is periodically sampled and not 100% tested. Test Circuit #1Test Circuit #2Circuit #3 SPICE Macro Model V V H/RH H/RH RTOTAL Test Point RH RL CL CW V CH S Test Point VW V 10pF W/RW VW/RW Force 25pF Current 10pF V L VL/RL L/RL RW A.C. CONDITIONS OF TEST Input pulse levels 0V to 3V Input rise and fall times 10ns Input reference levels 1.5V 5 FN8176.0 March 15, 2005