Datasheet LT3681 (Analog Devices) - 3

FabricanteAnalog Devices
Descripción36V, 2A, 2.8MHz Step-Down Switching Regulator with Integrated Power Schottky Diode
Páginas / Página24 / 3 — The. ELECTRICAL CHARACTERISTICS. denotes the specifi cations which apply …
Formato / tamaño de archivoPDF / 381 Kb
Idioma del documentoInglés

The. ELECTRICAL CHARACTERISTICS. denotes the specifi cations which apply over the full operating

The ELECTRICAL CHARACTERISTICS denotes the specifi cations which apply over the full operating

Línea de modelo para esta hoja de datos

Versión de texto del documento

LT3681
The ELECTRICAL CHARACTERISTICS

denotes the specifi cations which apply over the full operating temperature range, otherwise specifi cations are at TA = 25°C. VIN = 10V, VRUNS/SS = 10V VBOOST = 15V, VBIAS = 3.3V unless otherwise noted. (Note 2) PARAMETER CONDITIONS MIN TYP MAX UNITS
Power Schottky Diode Forward Voltage IDA = 1A 0.50 V IDA = 2A 0.56 V Power Schottky Diode Leakage Current VDC-DA = 40V 100 μA Switching Frequency RT = 8.66k 2.5 2.8 3.1 MHz RT = 29.4k 1.25 1.4 1.55 MHz RT = 187k 250 300 350 kHz Minimum Switch Off-Time ● 130 200 nS Switch Current Limit Duty Cycle = 5% 3.2 3.8 4.4 A Switch VCESAT ISW = 2A 360 mV Boost Schottky Reverse Leakage VSW = 10V, VBIAS = 0V 0.02 2 µA Minimum Boost Voltage (Note 4) ● 1.5 2.1 V BOOST Pin Current ISW = 1A 18 35 mA RUN/SS Pin Current VRUN/SS = 2.5V 5 10 μA RUN/SS Input Voltage High 2.5 V RUN/SS Input Voltage Low 0.2 V PG Threshold Offset from Feedback Voltage VFB Rising 122 mV PG Hysteresis 5 mV PG Leakage VPG = 5V 0.1 1 μA PG Sink Current VPG = 3V ● 100 600 μA
Note 1:
Stresses beyond those listed under Absolute Maximum Ratings
Note 3:
Bias current fl ows into the FB pin. may cause permanent damage to the device. Exposure to any Absolute
Note 4:
This is the minimum voltage across the boost capacitor needed to Maximum Rating condition for extended periods may affect device guarantee full saturation of the switch. reliability and lifetime.
Note 2:
The LT3681E is guaranteed to meet performance specifi cations from 0°C to 85°C. Specifi cations over the –40°C to 85°C operating temperature range are assured by design, characterization and correlation with statistical process controls. 3681f 3