LTC6401-26 AC ELECTRICAL CHARACTERISTICSSpecifi cations are at TA = 25°C. V+ = 3V, V– = 0V, VOCM = 1.25V, ⎯ E ⎯ N ⎯ A ⎯ B ⎯ L ⎯ E = 0V, No RL unless otherwise noted.SYMBOLPARAMETERCONDITIONSMINTYPMAXUNITS140MHz Input Signal HD2,140M/ Second/Third Order Harmonic Distortion VOUT = 2VP-P , RL = 200Ω –81/–54 dBc HD3,140M VOUT = 2VP-P , No RL –85/–69 dBc IMD3,140M Third-Order Intermodulation VOUT = 2VP-P Composite, RL = 200Ω –64 dBc (f1 = 139.5MHz f2 = 140.5MHz) VOUT = 2VP-P Composite, No RL –72 dBc OIP3,140M Equivalent Third-Order Output Intercept VOUT = 2VP-P Composite, No RL (Note 7) 40 dBm Point(f1 = 139.5MHz f2 = 140.5MHz) P1dB,140M 1dB Compression Point RL = 375Ω (Notes 5, 7) 17.4 dBm NF140M Noise Figure RL = 375Ω (Note 5) 6.5 dB eN,140M Input Referred Voltage Noise Density Includes Resistors (Short Inputs) 1.43 nV/√⎯H⎯z eON,140M Output Referred Voltage Noise Density Includes Resistors (Short Inputs) 28.6 nV/√⎯H⎯z IMD3,130M/150M Third-Order Intermodulation VOUT = 2VP-P Composite, RL = 375Ω –70 –62 dBc (f1 = 130MHz f2 = 150MHz) Measure at 170MHz Note 1: Stresses beyond those listed under Absolute Maximum Ratings temperatures. The LTC6401I is guaranteed to meet specifi ed performance may cause permanent damage to the device. Exposure to any Absolute from –40°C to 85°C. Maximum Rating condition for extended periods may affect device Note 5: Input and output baluns used. See Test Circuit A. reliability and lifetime. Note 6: Measured using Test Circuit B. RL = 87.5Ω per output. Note 2: Input pins (+IN, –IN) are protected by steering diodes to either Note 7: Since the LTC6401-26 is a feedback amplifi er with low output supply. If the inputs go beyond either supply rail, the input current should impedance, a resistive load is not required when driving an AD converter. be limited to less than 10mA. Therefore, typical output power is very small. In order to compare the Note 3: The LTC6401C and LTC6401I are guaranteed functional over the LTC6401-26 with amplifi ers that require 50Ω output load, the output operating temperature range of –40°C to 85°C voltage swing driving a given RL is converted to OIP3 and P1dB as if it were Note 4: The LTC6401C is guaranteed to meet specifi ed performance from driving a 50Ω load. Using this modifi ed convention, 2VP-P is by defi nition 0°C to 70°C. It is designed, characterized and expected to meet specifi ed equal to 10dBm, regardless of actual RL. performance from –40°C to 85°C but is not tested or QA sampled at these 640126f 5