TABLE I. Electrical performance characteristics – Continued. Conditions Test Symbol -55°C ≤ TA ≤ +125°C Group A Device Limits 1/ Unit ±V subgroups type S = ±15 V unless otherwise specified Min Max Slew rate 5/ SR AV = +10, RL = 500 Ω, 4 01 94 V/µs CL = 100 pF, TA = +25°C 1/ The magnitude convention is used to establish the limits for these tests. 2/ Bias current parameters are guaranteed maximum after the equivalent of five minutes at TA = +25°C. 3/ This parameter is guaranteed by testing common mode rejection ratio. 4/ Input offset current parameters are guaranteed maximum after the equivalent of five minutes at TA = +25°C. 5/ If not tested, this parameter shall be guaranteed to the limits specified in table I herein. 3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DLA Land and Maritime -VA prior to listing as an approved source of supply shall affirm that the manufacturer's product meets the requirements of MIL-PRF-38535, appendix A and the requirements herein. 3.7 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing. 3.8 Notification of change. Notification of change to DLA Land and Maritime -VA shall be required for any change that affects this drawing. 3.9 Verification and review. DLA Land and Maritime, DLA Land and Maritime's agent, and the acquiring activity retain the option to review the manufacturer's facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the reviewer. STANDARD SIZE A5962-89645MICROCIRCUIT DRAWING DLA LAND AND MARITIME REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 C 5 DSCC FORM 2234 APR 97