Data SheetADIS16136TYPICAL PERFORMANCE CHARACTERISTICS100+1σ0.20INITIAL BIAS ERROR = ±0.1°AVERAGEBIAS TEMPERATURE COEFFICIENT = ±0.00125°/sec/°C–1σ0.150.10°/Hr) (°/sec) 0.05ANCER (ARI V100RRO EANTLE S –0.05ALF F OOOT–0.10R–0.151–0.200.010.1110100100010000–40–30–20–10010203040506070 027 025 TTEMPERATURE (°C)AU (Seconds) 10249- 10249- Figure 7. Root Al an Variance, 5 V, 25°C, 1024 SPS Figure 9. Offset (Bias) Error vs. Temperature, −40°C to +75°C to −40°C 0.600.40INITIAL SENSITIVITY ERROR = ±0.35%%)SENSITIVITIY TEMPC = ±25ppm/°C0.20R (RRO E Y0T IVI T SI –0.20 SEN–0.40–0.60–45 –35 –25 –15 –5 5 15 25 35 45 55 65 75 026 TEMPERATURE (°C) 10249- Figure 8. Sensitivity Error vs. Temperature, −40°C to +75°C to −40°C Rev. D | Page 7 of 20 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS TIMING SPECIFICATIONS Timing Diagrams ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS THEORY OF OPERATION READING SENSOR DATA OUTPUT DATA REGISTERS Rotation Rate (Gyroscope) Internal Temperature DEVICE CONFIGURATION Dual Memory Structure USER REGISTERS DIGITAL PROCESSING CONFIGURATION INTERNAL SAMPLE RATE INPUT CLOCK CONFIGURATION DIGITAL FILTERING AVERAGING/DECIMATION FILTER CALIBRATION AUTOMATIC BIAS CORRECTION (AUTONULL) MANUAL BIAS CORRECTION Restoring Factory Calibration ALARMS STATIC ALARM USE DYNAMIC ALARM USE ALARM REPORTING Alarm Example SYSTEM CONTROLS GLOBAL COMMANDS Software Reset MEMORY MANAGEMENT Checksum Test GENERAL-PURPOSE INPUT/OUTPUT Data Ready Input/Output Indicator Example Input/Output Configuration AUTOMATIC SELF TEST POWER MANAGEMENT STATUS PRODUCT IDENTIFICATION APPLICATIONS INFORMATION POWER SUPPLY CONSIDERATIONS PROTOTYPE INTERFACE BOARD INSTALLATION TIPS PACKAGING AND ORDERING INFORMATION OUTLINE DIMENSIONS ORDERING GUIDE