TABLE IA. Electrical performance characteristics – Continued. Test Symbol Conditions 1/ 2/ Group A Device Limits Unit -55°C ≤ TA ≤ +125°C subgroups type VSY = ±5.0 V, VCM = 0 V unless otherwise specified Min Max Input characteristics Offset voltage VOS 1 01, 02 25 µV 2, 3 65 M,D,P,L,R 1 01 25 D,P,L 1 02 25 Offset voltage drift 3/ 5/ ∆VOS/∆T 1, 2, 3 01, 02 0.3 µV/°C Input bias current IB 1 01, 02 -1 +1 nA 2, 3 -1.5 +1.5 M,D,P,L,R 1 01 -1 +1 D,P,L 1 02 -1 +1 Input offset current IOS 1 01, 02 -0.5 +0.5 nA 2, 3 -1 +1 M,D,P,L,R 1 01 -0.5 +0.5 D,P,L 1 02 -0.5 +0.5 Input voltage range 4/ IVR 1, 2, 3 01, 02 -3.8 +3 V M,D,P,L,R 1 01 -3.8 +3 D,P,L 1 02 -3.8 +3 Common-mode rejection ratio CMRR VCM = -3.8 V to +3 V 1 01, 02 122 dB 2 112 3 120 M,D,P,L,R 1 01 122 D,P,L 1 02 122 Large signal voltage gain AV RL = 2 kΩ, 1 01, 02 121 dB VOUT = -3.0 V to +3.0 V 2, 3 120 M,D,P,L,R 1 01 121 D,P,L 1 02 121 See footnotes at end of table. STANDARD SIZE 5962-14233MICROCIRCUIT DRAWINGA DLA LAND AND MARITIME REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 A 9 DSCC FORM 2234 APR 97 Document Outline DEPARTMENT OF DEFENSE SPECIFICATION DEPARTMENT OF DEFENSE STANDARDS