Datasheet Texas Instruments BQ20Z70PW-V150 — Ficha de datos
Fabricante | Texas Instruments |
Serie | BQ20Z70-V150 |
Numero de parte | BQ20Z70PW-V150 |
Indicador de gas compatible con SBS 1.1 habilitado con tecnología de seguimiento de impedancia para usar con el bq29330 20-TSSOP -40 a 85
Hojas de datos
SBS 1.1 Compliant Gas Gauge Enabled w/Impedance Track Tech for bq29330 datasheet
PDF, 780 Kb, Revisión: B, Archivo publicado: oct 17, 2006
Extracto del documento
Precios
Estado
Estado del ciclo de vida | NRND (No recomendado para nuevos diseños) |
Disponibilidad de muestra del fabricante | No |
Embalaje
Pin | 20 |
Package Type | PW |
Industry STD Term | TSSOP |
JEDEC Code | R-PDSO-G |
Package QTY | 70 |
Carrier | TUBE |
Device Marking | 20Z70 |
Width (mm) | 4.4 |
Length (mm) | 6.5 |
Thickness (mm) | 1 |
Pitch (mm) | .65 |
Max Height (mm) | 1.2 |
Mechanical Data | Descargar |
Plan ecológico
RoHS | Obediente |
Kits de diseño y Módulos de evaluación
- Evaluation Modules & Boards: BQTESTER
Single Channel Tester
Estado del ciclo de vida: Activo (Recomendado para nuevos diseños) - Evaluation Modules & Boards: BQMTESTER
BQMTESTER Multi Channel Test and Program Board
Estado del ciclo de vida: Activo (Recomendado para nuevos diseños)
Notas de aplicación
- bq20z70-V110 to bq20z70-V150 Change ListPDF, 34 Kb, Archivo publicado: enero 11, 2008
bq20z70-V150 Design Considerations - Cell-type Specific Settings for Cell Imbalance Permanent Failure ThresholdsPDF, 100 Kb, Archivo publicado: sept 28, 2007
- 2-Series-Cell Considerations for Advanced Fuel GaugesPDF, 154 Kb, Archivo publicado: mayo 9, 2008
- Operating Fuel Gauge bq20z7x/8x/9x and SMBus-Like bq24745/47/65 ChargersPDF, 132 Kb, Archivo publicado: oct 6, 2009
The smart charger bq24747/765 is a high-efficiency, synchronous battery charger with an integrated input current comparator. This charger provides low component count for space constrained, multichemistry battery charging applications. SMBus input current, charge current, and input current digital-to-analog converters allow for very high regulation accuracies that the system power management micr - Cell Balancing Using the bq20zxx (Rev. C)PDF, 208 Kb, Revisión: C, Archivo publicado: enero 12, 2011
This application report discusses three types of cell imbalances that are observed in a battery pack withserially connected cells. - Updating Firmware With the bq20zxx and EVM (Rev. B)PDF, 54 Kb, Revisión: B, Archivo publicado: nov 7, 2006
This application report presents the steps necessary to update the bq20z80 firmware and the EVM. - Pack Assembly and the bq20zxx (Rev. B)PDF, 35 Kb, Revisión: B, Archivo publicado: nov 7, 2006
This application report describes a recommended assembly sequence for the bq20z80-based battery pack. This procedure results in the most time-efficient setup of the battery pack. Included are steps for connecting a 4-series cell battery to the bq20z80EVM-001. - Thermistor Coefficient Calculator for TI Advanced Fuel GaugesPDF, 58 Kb, Archivo publicado: oct 4, 2006
- Evaluation 7: Preparing Optimized Data Flash Constants (Rev. B)PDF, 29 Kb, Revisión: B, Archivo publicado: dic 4, 2006
Impedance Track в„ў technology allows bq20z80 fuel gauge ICs to automatically acquire and maintain parameters for battery modeling needed for continuous fuel-gauge accuracy, regardless of battery model or manufacturer. This application report discusses how to prepare optimized default flash constants for specific battery types. - bq29330 External Short Circuit ProtectionPDF, 155 Kb, Archivo publicado: agosto 22, 2007
In Li-ion battery pack design, short-circuit protection should be given sufficient emphasis to ensure that even if an external pack short does occur, it is benign. Properly designed battery fuel gauge solutions using the bq29330 analog front-end (AFE) protector and bq20z70, bq20z75, bq20z90, and bq20z95 fuel gauge ICs not only safeguards the battery, but also ensures a full recovery of functionali - Design 4: Support of Multiple Li-Ion Chemistries w/Impedance Track(TM) Gas Gauge (Rev. R)PDF, 87 Kb, Revisión: R, Archivo publicado: oct 15, 2009
- bq20z70 and bq20z90 Application BookPDF, 14.2 Mb, Archivo publicado: dic 13, 2006
This document introduces the bq20z70/z90 Impedance Trackв„ў and bq29330 chipset gas gauge solution - Quick-Start Guide for bq20zxx Family Gas Gauges (Rev. A)PDF, 4.4 Mb, Revisión: A, Archivo publicado: sept 4, 2007
The intent of this application report is to give the user an overview of the design process, how to use the evaluation module and software, and to provide helpful troubleshooting techniques.This document begins with setting up the evaluation module and working with bq Evaluation Software. Several tips for troubleshooting the software connection are included, as well as navigation and what to l - Fast Cell Balancing Using External MOSFET (Rev. A)PDF, 153 Kb, Revisión: A, Archivo publicado: enero 26, 2009
The need for cell balancing comes from the fact that cell-to-cell differences in self-discharge, capacity, and impedance can lead to different charge states among the cells. However, the charger terminates the charge based on the summed voltage only, which may leave some cells undercharged and others overcharged. To remedy this imbalance and to achieve the goal of having all cells reaching 100% st
Linea modelo
Serie: BQ20Z70-V150 (2)
- BQ20Z70PW-V150 BQ20Z70PWR-V150
Clasificación del fabricante
- Semiconductors > Power Management > Battery Management Products > Battery Fuel Gauge
Otros nombres:
BQ20Z70PWV150, BQ20Z70PW V150