Datasheet Texas Instruments OPA128LM — Ficha de datos
Fabricante | Texas Instruments |
Serie | OPA128 |
Numero de parte | OPA128LM |
Amplificador operacional de grado electrómetro 8-TO-99 -55 a 125
Hojas de datos
Datasheet OPA128
PDF, 138 Kb, Archivo publicado: sept 27, 2000, Páginas: 11
Difet Electrometer-Grade Operational Amplifier
Difet Electrometer-Grade Operational Amplifier
Extracto del documento
Precios
Estado
Estado del ciclo de vida | Activo (Recomendado para nuevos diseños) |
Disponibilidad de muestra del fabricante | Sí |
Embalaje
Pin | 8 |
Package Type | LMC |
Industry STD Term | TO-CAN |
JEDEC Code | O-MBCY-W |
Package QTY | 20 |
Carrier | TUBE |
Device Marking | OPA128LM |
Width (mm) | 9.08 |
Length (mm) | 9.08 |
Thickness (mm) | 4.4 |
Pitch (mm) | 2.54 |
Max Height (mm) | 5.72 |
Mechanical Data | Descargar |
Paramétricos
Additional Features | N/A |
Architecture | FET |
CMRR(Min) | 80 dB |
CMRR(Typ) | 118 dB |
GBW(Typ) | 1 MHz |
Input Bias Current(Max) | 0.075 pA |
Iq per channel(Max) | 1.8 mA |
Iq per channel(Typ) | 0.9 mA |
Number of Channels | 1 |
Offset Drift(Typ) | 5 uV/C |
Operating Temperature Range | -55 to 125 C |
Output Current(Typ) | 34 mA |
Package Group | TO-99 |
Package Size: mm2:W x L | 8TO-99: 80 mm2: 8.96 x 8.96(TO-99) PKG |
Rail-to-Rail | Out |
Rating | Catalog |
Slew Rate(Typ) | 3 V/us |
Total Supply Voltage(Max) | 36 +5V=5, +/-5V=10 |
Total Supply Voltage(Min) | 10 +5V=5, +/-5V=10 |
Vn at 1kHz(Typ) | 27 nV/rtHz |
Vos (Offset Voltage @ 25C)(Max) | 0.5 mV |
Plan ecológico
RoHS | Obediente |
Notas de aplicación
- Designing Photodiode Amplifier Circuits with OPA128PDF, 76 Kb, Archivo publicado: oct 2, 2000
The OPA128 ultra-low bias current operational amplifier achieves its 75fA maximum bias current without compromise. Using standard design techniques, serious performance trade-offs were required which sacrificed overall amplifier performance in order to reach femtoamp (fA = 10-15A) bias currents. - Diode-Connected FET Protects Op AmpsPDF, 49 Kb, Archivo publicado: oct 2, 2000
Providing input-overload protection for sensitive measurement circuits proves difficult when you must not degrade the circuits? performance in the process. It?s an especially tricky problem when you?re measuring a material?s dielectric properties. In such an application, an ultra-low input bias current op amp serves as a current integrator to measure a dielectric?s response to a 100V step. - Boost Instrument Amp CMR With Common-Mode Driven SuppliesPDF, 175 Kb, Archivo publicado: sept 27, 2000
Ever-increasing demands are being placed on instrumentation amplifier (IA) performance. When standard IAs can not deliver the required performance, consider this enhanced version. Dramatic performance improvements can be achieved by operating the input amplifiers of a classical three-op-amp IA from common-mode driven sub-regulated power supplies. - Comparison of Noise Performance of FET Transimpedence Amp/Switched IntegratorPDF, 66 Kb, Archivo publicado: sept 27, 2000
Low-input current FET operational amplifiers are universlly used to monitor photodetector, or more commonly photodiode currents. These photodetectors bridge the gap between a physical event, light, and electronics. There are a variey of amplifier configurations to select from and the choice is based on noise, bandwidth, offset, and linearity. A considerable amount has been written on the performan - Compensate Transimpedance Amplifiers Intuitively (Rev. A)PDF, 69 Kb, Revisión: A, Archivo publicado: marzo 30, 2005
Transimpedance amplifiers are used to convert low-level photodiode currents to usable voltage signals. All too often, the amplifiers have to be empirically compensated to operate properly. The problem can be easily understood if one looks at all the elements involved. - Tuning in AmplifiersPDF, 44 Kb, Archivo publicado: oct 2, 2000
Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil - Single-Supply Operation of Operational AmplifiersPDF, 77 Kb, Archivo publicado: oct 2, 2000
Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation. - Op Amp Performance AnalysisPDF, 76 Kb, Archivo publicado: oct 2, 2000
This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte
Linea modelo
Clasificación del fabricante
- Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Precision Op Amps