Datasheet Texas Instruments OPA1692IDGK — Ficha de datos

FabricanteTexas Instruments
SerieOPA1692
Numero de parteOPA1692IDGK
Datasheet Texas Instruments OPA1692IDGK

SoundPlus Amplificador operacional de doble entrada de audio bipolar de baja potencia, bajo ruido y alto rendimiento 8-VSSOP -40 a 85

Hojas de datos

в„ў OPA169x Low-Power, Low-Noise and Low-Distortion Audio Operational Amplifiers datasheet
PDF, 482 Kb, Archivo publicado: jun 29, 2017
Extracto del documento

Precios

Estado

Estado del ciclo de vidaVista previa (El dispositivo ha sido anunciado pero no está en producción. Las muestras pueden o no estar disponibles)
Disponibilidad de muestra del fabricanteNo

Embalaje

Pin8
Package TypeDGK
Industry STD TermVSSOP
JEDEC CodeR-PDSO-G
Package QTY80
Width (mm)3
Length (mm)3
Thickness (mm).97
Pitch (mm).65
Max Height (mm)1.07
Mechanical DataDescargar

Paramétricos

Additional FeaturesBurr-Brownв„ў Audio
ArchitectureBipolar
CMRR(Min)120 dB
CMRR(Typ)140 dB
GBW(Typ)5.7 MHz
Input Bias Current(Max)350000 pA
Iq per channel(Max)0.75 mA
Iq per channel(Typ)0.65 mA
Number of Channels2
Offset Drift(Typ)0.5 uV/C
Operating Temperature Range-40 to 85 C
Output Current(Typ)50 mA
Package GroupVSSOP
Package Size: mm2:W x L8VSSOP: 15 mm2: 4.9 x 3(VSSOP) PKG
Rail-to-RailOut
RatingCatalog
Slew Rate(Typ)21 V/us
Total Supply Voltage(Max)36 +5V=5, +/-5V=10
Total Supply Voltage(Min)3.5 +5V=5, +/-5V=10
Vn at 1kHz(Typ)4.2 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)0.5 mV

Plan ecológico

RoHSSee ti.com

Notas de aplicación

  • Compensate Transimpedance Amplifiers Intuitively (Rev. A)
    PDF, 69 Kb, Revisión: A, Archivo publicado: marzo 30, 2005
    Transimpedance amplifiers are used to convert low-level photodiode currents to usable voltage signals. All too often, the amplifiers have to be empirically compensated to operate properly. The problem can be easily understood if one looks at all the elements involved.
  • Tuning in Amplifiers
    PDF, 44 Kb, Archivo publicado: oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Archivo publicado: oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, Archivo publicado: oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Linea modelo

Serie: OPA1692 (4)

Clasificación del fabricante

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Precision Op Amps