Datasheet Texas Instruments LMP7721 — Ficha de datos

FabricanteTexas Instruments
SerieLMP7721
Datasheet Texas Instruments LMP7721

Amplificador de precisión de corriente de polarización de entrada de 3 femtoamperios

Hojas de datos

LMP7721 3-Femtoampere Input Bias Current Precision Amplifier datasheet
PDF, 1.0 Mb, Revisión: E, Archivo publicado: dic 15, 2014
Extracto del documento

Precios

Estado

LMP7721MA/NOPBLMP7721MAX/NOPB
Estado del ciclo de vidaActivo (Recomendado para nuevos diseños)Activo (Recomendado para nuevos diseños)
Disponibilidad de muestra del fabricanteNo

Embalaje

LMP7721MA/NOPBLMP7721MAX/NOPB
N12
Pin88
Package TypeDD
Industry STD TermSOICSOIC
JEDEC CodeR-PDSO-GR-PDSO-G
Package QTY952500
CarrierTUBELARGE T&R
Device MarkingLMP7721MA
Width (mm)3.913.91
Length (mm)4.94.9
Thickness (mm)1.581.58
Pitch (mm)1.271.27
Max Height (mm)1.751.75
Mechanical DataDescargarDescargar

Paramétricos

Parameters / ModelsLMP7721MA/NOPB
LMP7721MA/NOPB
LMP7721MAX/NOPB
LMP7721MAX/NOPB
Additional FeaturesN/AN/A
ArchitectureCMOSCMOS
CMRR(Min), dB8484
CMRR(Typ), dB100100
GBW(Typ), MHz1717
Input Bias Current(Max), pA0.020.02
Iq per channel(Max), mA1.71.7
Iq per channel(Typ), mA1.31.3
Number of Channels11
Offset Drift(Typ), uV/C1.51.5
Operating Temperature Range, C-40 to 125-40 to 125
Output Current(Typ), mA2222
Package GroupSOICSOIC
Package Size: mm2:W x L, PKG8SOIC: 29 mm2: 6 x 4.9(SOIC)8SOIC: 29 mm2: 6 x 4.9(SOIC)
Rail-to-RailIn to V-,OutIn to V-,Out
RatingCatalogCatalog
Slew Rate(Typ), V/us10.510.5
Total Supply Voltage(Max), +5V=5, +/-5V=105.55.5
Total Supply Voltage(Min), +5V=5, +/-5V=101.81.8
Vn at 1kHz(Typ), nV/rtHz6.56.5
Vos (Offset Voltage @ 25C)(Max), mV0.150.15

Plan ecológico

LMP7721MA/NOPBLMP7721MAX/NOPB
RoHSObedienteObediente

Notas de aplicación

  • AN-1798 Designing with Electro-Chemical Sensors (Rev. C)
    PDF, 62 Kb, Revisión: C, Archivo publicado: mayo 1, 2013
    As early as 1950, electro-chemical sensors were used for oxygen (gas) monitoring; however, with increasing concerns about personal safety, the demand for portable electro-chemical sensors has dramatically increased. Today, electro-chemical sensors are commonly used in portable equipment todetect different toxic gases.
  • AN-1852 Designing With pH Electrodes (Rev. A)
    PDF, 115 Kb, Revisión: A, Archivo publicado: mayo 1, 2013
    A pH electrode measures hydrogen ion (H+) activity and produces an electrical potential or voltage. Theoperation of the pH electrode is based on the principle that an electric potential develops when two liquidsof different pH come into contact at opposite sides of a thin glass membrane. This was originallydiscovered in 1906 by Max Cremer [1]. His discovery laid the foundation for Fritz Habe

Linea modelo

Clasificación del fabricante

  • Semiconductors> Amplifiers> Operational Amplifiers (Op Amps)> Precision Op Amps