Amplificador operacional cuádruple 14-PDIP 0 a 70
PDF, 682 Kb, Archivo publicado: mayo 2, 2004
PDF, 88 Kb, Archivo publicado: oct 1, 2002
PDF, 727 Kb, Revisión: C, Archivo publicado: mayo 1, 2013
This application note is a guide for Op Amps. The circuits discussed herein are illustrative of the versatilityof the integrated operational amplifier and provide a guide to a number of useful applications. Thecautions noted in each section will show the more common pitfalls encountered in amplifier usage.
PDF, 1.2 Mb, Archivo publicado: mayo 10, 2004
Application Note 24 A Simplified Test Set for Op Amp Characterization
PDF, 965 Kb, Revisión: B, Archivo publicado: mayo 1, 2013
This application note describes a monolithic operational amplifier which has input error currents in theorder of 100 pA over a в€’55В°C to 125В°C temperature range. Instead of FETs, the circuit used bipolartransistors with current gains of 5000 so that offset voltage and drift are not degraded. A powerconsumption of 1 mW at low voltage is also featured.A number of novel circuits that make use
PDF, 254 Kb, Archivo publicado: mayo 10, 2004
PDF, 579 Kb, Revisión: B, Archivo publicado: mayo 1, 2013
Operational amplifiers are undoubtedly the easiest and best way of performing a wide range of linearfunctions from simple amplification to complex analog computation. The cost of monolithic amplifiers isnow less than $2.00, in large quantities, which makes it attractive to design them into circuits where theywould not otherwise be considered. Yet low cost is not the only attraction of monoli
PDF, 169 Kb, Archivo publicado: mayo 3, 2004
Application Note 241 Working with High Impedance Op Amps
PDF, 2.3 Mb, Revisión: B, Archivo publicado: mayo 1, 2013
This application report provides basic circuits of the Texas Instruments op amp collection.
PDF, 142 Kb, Archivo publicado: mayo 10, 2004
Application Brief 24 Bench Testing LM3900 and LM359 Input Parameters
PDF, 782 Kb, Archivo publicado: mayo 10, 2004
Application Note 446 A 150W IC Op Amp Simplifies Design of Power Circuits
PDF, 1.2 Mb, Revisión: A, Archivo publicado: sept 19, 2016
It is well known that the voltage noise of an operational amplifier can be decreased by increasing the emitter currentof the input stage. The signal-to-noise ratio will be improved by the increase of bias, until the base current noise begins to dominate.
PDF, 94 Kb, Archivo publicado: oct 3, 2002
PDF, 80 Kb, Archivo publicado: oct 2, 2002
PDF, 379 Kb, Archivo publicado: mayo 11, 2004
PDF, 314 Kb, Archivo publicado: mayo 14, 2004
PDF, 71 Kb, Archivo publicado: oct 2, 2002
PDF, 139 Kb, Archivo publicado: oct 7, 2002
PDF, 502 Kb, Revisión: B, Archivo publicado: mayo 5, 2013
This application report discusses how combining an “inferior”, 20 year old A/D conversion technique with amicroprocessor, a developmental A/D converter achieves 1 part-per-million (20-bit) linearity.
PDF, 421 Kb, Archivo publicado: oct 4, 2004
PDF, 370 Kb, Revisión: B, Archivo publicado: mayo 1, 2013
One of the most predictable non-linear elements commonly available is the bipolar transistor. Therelationship between collector current and emitter base voltage is precisely logarithmic from currentsbelow one picoamp to currents above one milliamp. Using a matched pair of transistors and integratedcircuit operational amplifiers it is relatively easy to construct a linear to logarithmic conv
PDF, 867 Kb, Revisión: B, Archivo publicado: abr 23, 2013
This application note provides new design ideas and discusses the positive impact of designing with theDual Norton amplifier.
PDF, 940 Kb, Revisión: B, Archivo publicado: mayo 1, 2013
Since the introduction of monolithic IC amplifiers there has been a continual improvement in DC accuracy.Bias currents have been decreased by 5 orders of magnitude over the past 5 years. Low offset voltagedrift is also necessary in a high accuracy circuits. This is evidenced by the popularity of low drift amplifiertypes as well as the requests for selected low-drift op amps. However until n
PDF, 966 Kb, Revisión: B, Archivo publicado: mayo 5, 2013
This application report discusses how a super matched bipolar transistor pair sets new standards for driftand noise.
PDF, 218 Kb, Archivo publicado: mayo 11, 2004
PDF, 272 Kb, Archivo publicado: mayo 2, 2004
PDF, 107 Kb, Archivo publicado: oct 2, 2002
PDF, 1.1 Mb, Revisión: B, Archivo publicado: mayo 6, 2013
The availability of dual and quad packaged FET op amps offers the designer all the traditional capabilitiesof FET op amps including low bias current and speed and some additional advantages. The cost-peramplifieris lower because of reduced package costs. This means that more amplifiers are available toimplement a function at a given cost making design easier. At the same time the availab
PDF, 747 Kb, Revisión: C, Archivo publicado: abr 22, 2013
This application note describes the sine wave generation techniques to control frequency amplitude anddistortion levels.
PDF, 262 Kb, Revisión: B, Archivo publicado: mayo 6, 2013
Of all common environmental parameters humidity is perhaps the least understood and most difficult tomeasure. The most common electronic humidity detection methods albeit highly accurate are not obviousand tend to be expensive and complex (See Box). Accurate humidity measurement is vital to a number ofdiverse areas including food processing paper and lumber production pollution monitor
PDF, 91 Kb, Archivo publicado: oct 2, 2002