24 bits, 144 kHz, 8 canales, muestreo simultáneo, Delta-Sigma ADC 64-HTQFP -40 a 105

Hojas de datos

Quad/Octal, Simultaneous Sampling, 24-Bit Analog-to-Digital Converters datasheet
PDF, 1.7 Mb, Revisión: F, Archivo publicado: feb 17, 2011
Extracto del documento

Precios

Estado

Estado del ciclo de vidaActivo (Recomendado para nuevos diseños)
Disponibilidad de muestra del fabricanteNo

Embalaje

Pin64
Package TypePAP
Industry STD TermHTQFP
JEDEC CodeS-PQFP-G
Package QTY1000
CarrierLARGE T&R
Device MarkingADS1278
Width (mm)10
Length (mm)10
Thickness (mm)1
Pitch (mm).5
Max Height (mm)1.2
Mechanical DataDescargar

Paramétricos

# Input Channels8
Analog Voltage AVDD(Max)5.25 V
Analog Voltage AVDD(Min)4.75 V
ArchitectureDelta-Sigma
Digital Supply(Max)2.2 V
Digital Supply(Min)1.65 V
INL(Max)201.4 +/-LSB
Input Range(Max)5.25 V
Input TypeDifferential
Integrated FeaturesDaisy-Chainable
InterfaceSPI
Multi-Channel ConfigurationSimultaneous Sampling
Operating Temperature Range-40 to 105 C
Package GroupHTQFP
Package Size: mm2:W x L64HTQFP: 144 mm2: 12 x 12(HTQFP) PKG
Power Consumption(Typ)530 mW
RatingCatalog
Reference ModeExt
Resolution24 Bits
SNR111 dB
Sample Rate (max)144kSPS SPS
Sample Rate(Max)0.128 MSPS
THD(Typ)-108 dB

Plan ecológico

RoHSObediente

Kits de diseño y Módulos de evaluación

  • Evaluation Modules & Boards: ADS1278EVM-PDK
    ADS1278 Performance Demonstration Kit
    Estado del ciclo de vida: Activo (Recomendado para nuevos diseños)

Notas de aplicación

  • Using single-supply fully diff. amps with neg. input voltages to drive ADCs
    PDF, 105 Kb, Archivo publicado: nov 15, 2010
  • 4Q 2010 Issue Analog Applications Journal
    PDF, 1.3 Mb, Archivo publicado: nov 15, 2010
  • Analog Front-End Design for ECG Systems Using Delta-Sigma ADCs (Rev. A)
    PDF, 191 Kb, Revisión: A, Archivo publicado: abr 13, 2010
    This document discusses the characteristics of electrocardiogram (ECG) signals and different front-endapproaches for ECG signal acquisition. The tradeoffs between different approaches and the effects on overall system design are discussed. The report also includes descriptions of potential implementations of the front-end architecture using the ADS1258 and ADS1278 and respective noise measuremen
  • Digital Filter Types in Delta-Sigma ADCs
    PDF, 219 Kb, Archivo publicado: jun 27, 2017
    This application report discusses digital filters which are a ubiquitous feature in delta-sigma analog todigital converters (ADCs). Digital low-pass filters are essential to the functionality of a delta-sigma ADCwhich relies on oversampling and noise shaping to push quantization noise out of band. There arevariations between the types of digital filters used in delta-sigma ADCs that provide
  • Analog-to-Digital Converter Grounding Practices Affect System Performance (Rev. A)
    PDF, 69 Kb, Revisión: A, Archivo publicado: mayo 18, 2015
  • A Glossary of Analog-to-Digital Specifications and Performance Characteristics (Rev. B)
    PDF, 425 Kb, Revisión: B, Archivo publicado: oct 9, 2011
    This glossary is a collection of the definitions of Texas Instruments' Delta-Sigma (О”ОЈ), successive approximation register (SAR), and pipeline analog-to-digital (A/D) converter specifications and performance characteristics. Although there is a considerable amount of detail in this document, the product data sheet for a particular product specification is the best and final reference.
  • Principles of Data Acquisition and Conversion (Rev. A)
    PDF, 132 Kb, Revisión: A, Archivo publicado: abr 16, 2015

Linea modelo

Serie: ADS1278 (3)

Clasificación del fabricante

  • Semiconductors > Data Converters > Analog-to-Digital Converters (ADCs) > Precision ADCs (<=10MSPS)