Datasheet Texas Instruments OPA2137UA/2K5 — Ficha de datos

FabricanteTexas Instruments
SerieOPA2137
Numero de parteOPA2137UA/2K5
Datasheet Texas Instruments OPA2137UA/2K5

Amplificador operacional de entrada FET de bajo costo 8-SOIC -40 a 85

Hojas de datos

Low Cost FET-Input Operational Amplifiers datasheet
PDF, 775 Kb, Archivo publicado: sept 27, 2000
Extracto del documento

Precios

Estado

Estado del ciclo de vidaActivo (Recomendado para nuevos diseños)
Disponibilidad de muestra del fabricanteNo

Embalaje

Pin888
Package TypeDDD
Industry STD TermSOICSOICSOIC
JEDEC CodeR-PDSO-GR-PDSO-GR-PDSO-G
Package QTY250025002500
CarrierLARGE T&RLARGE T&RLARGE T&R
Device MarkingA2137UOPA
Width (mm)3.913.913.91
Length (mm)4.94.94.9
Thickness (mm)1.581.581.58
Pitch (mm)1.271.271.27
Max Height (mm)1.751.751.75
Mechanical DataDescargarDescargarDescargar

Paramétricos

Additional FeaturesN/A
ArchitectureFET
CMRR(Min)76 dB
CMRR(Typ)84 dB
GBW(Typ)1 MHz
Input Bias Current(Max)100 pA
Iq per channel(Max)0.27 mA
Iq per channel(Typ)0.22 mA
Number of Channels2
Offset Drift(Typ)15 uV/C
Operating Temperature Range-40 to 85 C
Output Current(Typ)25 mA
Package GroupSOIC
Package Size: mm2:W x L8SOIC: 29 mm2: 6 x 4.9(SOIC) PKG
Rail-to-RailIn to V+
RatingCatalog
Slew Rate(Typ)3.5 V/us
Total Supply Voltage(Max)36 +5V=5, +/-5V=10
Total Supply Voltage(Min)4.5 +5V=5, +/-5V=10
Vn at 1kHz(Typ)45 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)3 mV

Plan ecológico

RoHSObediente

Notas de aplicación

  • Tuning in Amplifiers
    PDF, 44 Kb, Archivo publicado: oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Archivo publicado: oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, Archivo publicado: oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Linea modelo

Clasificación del fabricante

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > General-Purpose Op Amps