Datasheet Texas Instruments OPA211SKGD1 — Ficha de datos

FabricanteTexas Instruments
SerieOPA211-HT
Numero de parteOPA211SKGD1
Datasheet Texas Instruments OPA211SKGD1

Alta temperatura 1.1nV / rtHz Ruido, baja potencia, amplificador operacional de precisión 0-XCEPT -55 a 210

Hojas de datos

1.1 nV/Hz Noise, Low Power, Precision Operational Amplifier datasheet
PDF, 468 Kb, Revisión: D, Archivo publicado: oct 3, 2013
Extracto del documento

Precios

Estado

Estado del ciclo de vidaActivo (Recomendado para nuevos diseños)
Disponibilidad de muestra del fabricanteNo

Embalaje

Package TypeKGD
Package QTY400

Paramétricos

Additional FeaturesShutdown
ArchitectureBipolar
CMRR(Min)110 dB
CMRR(Typ)120 dB
GBW(Typ)45 MHz
IIB(Max)250000 pA
Iq per channel(Max)7.5 mA
Iq per channel(Typ)3.6 mA
Number of Channels1
Offset Drift(Typ)2 uV/C
Operating Temperature Range-55 to 210 C
Output Current(Typ)30 mA
Package GroupCFP
Package Size: mm2:W x LSee datasheet (CFP) PKG
Rail-to-RailOut
RatingCatalog
Slew Rate(Typ)27 V/us
Total Supply Voltage(Max)36 +5V=5, +/-5V=10
Total Supply Voltage(Min)4.5 +5V=5, +/-5V=10
Vn at 1kHz(Typ)1.1 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)0.26 mV

Plan ecológico

RoHSSee ti.com

Kits de diseño y Módulos de evaluación

  • Evaluation Modules & Boards: HEATEVM
    Harsh Environment Acquisition Terminal (H.E.A.T) Evaluation Module Platform for High-Temperature App
    Estado del ciclo de vida: Obsoleto (El fabricante ha interrumpido la producción del dispositivo)

Notas de aplicación

  • Tuning in Amplifiers
    PDF, 44 Kb, Archivo publicado: oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Archivo publicado: oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, Archivo publicado: oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Linea modelo

Serie: OPA211-HT (3)

Clasificación del fabricante