Datasheet Texas Instruments LM324D — Ficha de datos
Fabricante | Texas Instruments |
Serie | LM324 |
Numero de parte | LM324D |
Amplificador operacional cuádruple 14-SOIC 0 a 70
Hojas de datos
Datasheet LM124, LM124A, LM124M, LM224, LM224A, LM224K, LM224KA, LM2902, LM2902K, LM2902KAV, LM2902KV, LM2902V, LM324, LM324A, LM324K, LM324KA
PDF, 1.8 Mb, Revisión: W, Archivo publicado: marzo 30, 2014, Páginas: 42
Quadruple Operational Amplifiers
Quadruple Operational Amplifiers
Extracto del documento
Precios
Estado
Estado del ciclo de vida | Activo (Recomendado para nuevos diseños) |
Disponibilidad de muestra del fabricante | Sí |
Embalaje
Pin | 14 |
Package Type | D |
Industry STD Term | SOIC |
JEDEC Code | R-PDSO-G |
Package QTY | 50 |
Carrier | TUBE |
Device Marking | LM324 |
Width (mm) | 3.91 |
Length (mm) | 8.65 |
Thickness (mm) | 1.58 |
Pitch (mm) | 1.27 |
Max Height (mm) | 1.75 |
Mechanical Data | Descargar |
Paramétricos
Additional Features | N/A |
Architecture | Bipolar |
CMRR(Min) | 65 dB |
CMRR(Typ) | 80 dB |
GBW(Typ) | 1.2 MHz |
Input Bias Current(Max) | 250000 pA |
Iq per channel(Max) | 0.3 mA |
Iq per channel(Typ) | 0.175 mA |
Number of Channels | 4 |
Offset Drift(Typ) | 7 uV/C |
Operating Temperature Range | 0 to 70 C |
Output Current(Typ) | 40 mA |
Package Group | SOIC |
Package Size: mm2:W x L | 14SOIC: 52 mm2: 6 x 8.65(SOIC) PKG |
Rail-to-Rail | In to V- |
Rating | Catalog |
Slew Rate(Typ) | 0.5 V/us |
Total Supply Voltage(Max) | 32 +5V=5, +/-5V=10 |
Total Supply Voltage(Min) | 3 +5V=5, +/-5V=10 |
Vn at 1kHz(Typ) | 35 nV/rtHz |
Vos (Offset Voltage @ 25C)(Max) | 7 mV |
Plan ecológico
RoHS | Obediente |
Notas de aplicación
- AN-260 A 20-Bit (1 ppm) Linear Slope-Integrating A/D Converter (Rev. B)PDF, 502 Kb, Revisión: B, Archivo publicado: mayo 5, 2013
This application report discusses how combining an “inferior”, 20 year old A/D conversion technique with amicroprocessor, a developmental A/D converter achieves 1 part-per-million (20-bit) linearity. - AN-30 Log Converters (Rev. B)PDF, 370 Kb, Revisión: B, Archivo publicado: mayo 1, 2013
One of the most predictable non-linear elements commonly available is the bipolar transistor. Therelationship between collector current and emitter base voltage is precisely logarithmic from currentsbelow one picoamp to currents above one milliamp. Using a matched pair of transistors and integratedcircuit operational amplifiers it is relatively easy to construct a linear to logarithmic conv - AN-278 Designing with a New Super Fast Dual Norton Amplifier (Rev. B)PDF, 867 Kb, Revisión: B, Archivo publicado: abr 23, 2013
This application note provides new design ideas and discusses the positive impact of designing with theDual Norton amplifier. - AN-79 IC Preamplifier Challenges Choppers on Drift (Rev. B)PDF, 940 Kb, Revisión: B, Archivo publicado: mayo 1, 2013
Since the introduction of monolithic IC amplifiers there has been a continual improvement in DC accuracy.Bias currents have been decreased by 5 orders of magnitude over the past 5 years. Low offset voltagedrift is also necessary in a high accuracy circuits. This is evidenced by the popularity of low drift amplifiertypes as well as the requests for selected low-drift op amps. However until n - Audio Applications of Linear Integrated CircuitsPDF, 272 Kb, Archivo publicado: mayo 2, 2004
- AN-262 Applying Dual and Quad FET Op Amps (Rev. B)PDF, 1.1 Mb, Revisión: B, Archivo publicado: mayo 6, 2013
The availability of dual and quad packaged FET op amps offers the designer all the traditional capabilitiesof FET op amps including low bias current and speed and some additional advantages. The cost-peramplifieris lower because of reduced package costs. This means that more amplifiers are available toimplement a function at a given cost making design easier. At the same time the availab - AN-263 Sine Wave Generation Techniques (Rev. C)PDF, 747 Kb, Revisión: C, Archivo publicado: abr 22, 2013
This application note describes the sine wave generation techniques to control frequency amplitude anddistortion levels. - AN-256 Circuitry for Inexpensive Relative Humidity Measurement (Rev. B)PDF, 262 Kb, Revisión: B, Archivo publicado: mayo 6, 2013
Of all common environmental parameters humidity is perhaps the least understood and most difficult tomeasure. The most common electronic humidity detection methods albeit highly accurate are not obviousand tend to be expensive and complex (See Box). Accurate humidity measurement is vital to a number ofdiverse areas including food processing paper and lumber production pollution monitor - Get More Power Out of Dual or Quad Op-AmpsPDF, 91 Kb, Archivo publicado: oct 2, 2002
Linea modelo
Serie: LM324 (22)
Clasificación del fabricante
- Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > General-Purpose Op Amps